OpenLegislation

Division B Determination of PFC emissions

United Kingdom

Original text. Later amendments are not shown.

PFC emissions shall be calculated from the emissions measurable in a duct or stack (‘point source emissions’) as well as fugitive emissions using the collection efficiency of the duct:

PFC emissions (total) = PFC emissions (duct)/collection efficiency

The collection efficiency shall be measured when the installation-specific emission factors are determined. For its determination the most recent version of the guidance mentioned under Tier 3 of section 4.4.2.4 of the 2006 IPCC Guidelines shall be used.

The operator shall calculate emissions of CF4 and C2F6 emitted through a duct or stack using one of the following methods:

  1. (a)

    Method A where the anode effect minutes per cell-day are recorded;

  2. (b)

    Method B where the anode effect overvoltage is recorded.

  1. Calculation Method A —Slope Method
  2. Calculation Method B —Overvoltage Method