# Commission Regulation (EU) No 601/2012 of 21 June 2012 on the monitoring and reporting of greenhouse gas emissions pursuant to Directive 2003/87/EC of the European Parliament and of the Council (Text with EEA relevance) (repealed), Division C: Emissions related to discarded dust

Extent: E+W+S+N.I.

The operator shall add CO2 emissions, from bypass dust or cement kiln dust (CKD) leaving the kiln system, corrected for a partial calcination ratio of CKD calculated as process emissions in accordance with Article 24(2). By way of derogation from section 4 of Annex II, tiers 1 and 2 for the emission factor shall be defined as follows:
Tier 1 The operator shall apply an emission factor of 0,525 t CO2/t dust.
Tier 2 The operator shall determine the emission factor (EF) at least once annually following Articles 32 to 35 and using the following formula:
EF CKD = EF Cli 1 + EF Cli * d 1 − EF Cli 1 + EF Cli * d Where:
EFCKD Emission factor of partially calcined cement kiln dust [t CO2/t CKD];
EFCli Installation-specific emission factor of clinker [t CO2/t clinker];
d Degree of CKD calcination (released CO2 as % of total carbonate CO2 in the raw mix).
Tier 3 for the emission factor is not applicable.

---
Source: https://www.legislation.gov.uk/eur/2012/601/annex/IV/division/9/division/C (the official version)
Page: https://openlegislation.uk/eu-regulation-2012-601/annex-IV/division-9/division-C
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.