  "text": "Annexes I and II to Regulation (EC) No 641/2009 are amended as follows:\n(1) Annex I, point 2, is replaced by the following:\n‘2.\nPRODUCT INFORMATION REQUIREMENTS\n1.\nFrom 1 January 2013:\n(a) the energy efficiency index of standalone circulators calculated in accordance with Annex II, shall be indicated on the name plate and packaging of the standalone circulator and in the technical documentation of the standalone circulator as follows: “EEI ≤ 0,[xx]”;\n(b) the following information shall be provided on standalone circulators and on circulators integrated in products: “The benchmark for the most efficient circulators is EEI ≤ 0,20.”;\n(c) information concerning disassembly, recycling, or disposal at end-of-life of components and materials, shall be made available for treatment facilities on standalone circulators and on circulators integrated in products;\n(d) for drinking water circulators, the following information shall be provided on the packaging and in the documentation: “This circulator is suitable for drinking water only”;\n(e) for circulators integrated in products and placed on the market no later than 1 January 2020 as replacement for identical circulators integrated in products and placed on the market no later than 1 August 2015, the replacement product or its packaging shall clearly indicate the product(s) for which it is intended.\nManufacturers shall provide information on how to install, use and maintain the circulator in order to minimise its impact on the environment.\nThe information listed above shall be visibly displayed on freely accessible websites of the circulator manufacturer.\n2.\nFrom 1 August 2015, for circulators integrated in products, the energy efficiency index calculated in accordance with Annex II, shall be indicated on the name plate of the circulator and in the technical documentation of the product as follows: “EEI ≤ 0,[xx]”.’;\n(2) Annex II, point 2, is replaced by the following:\n‘2.\nMETHODOLOGY FOR CALCULATING THE ENERGY EFFICIENCY INDEX\nThe methodology for calculating the energy efficiency index (EEI) for circulators is as follows:\n1.. Standalone circulators with pump housing shall be measured as a complete unit;\nStandalone circulators without pump housing shall be measured with pump housing identical to the pump housing in which they are intended to be used;\nCirculators integrated in products shall be dismantled from the product and measured with a reference pump housing;\nCirculators without pump housing intended to be integrated in a product shall be measured with a reference pump housing;\nwhere “reference pump housing” means a pump housing supplied by the manufacturer with inlet and outlet ports on the same axis and designed to be connected to the pipework of a heating system or secondary circuit of a cooling distribution system.\n2.. Where a circulator has more than one setting of head and flow, measure the circulator at the maximum setting.\n“Head” (H) means head (in metres) produced by the circulator at the specified point of operation.\n“Flow” (Q) means the volume flow rate of water through the circulator (m3/hr).\n3.. Find the point where Q · H is maximum and define the flow and head at this point as: Q100 % and H100 % .\n4.. Calculate the hydraulic power Phyd at this point.\n“Hydraulic power” means an expression of the arithmetic product of the flow (Q), Head (H) and a constant.\n“Phyd” means hydraulic power delivered by the circulator to the fluid being pumped at the specified point of operation (in watts).\n5.. Calculate the reference power as:\nPref = 1,7 · Phyd + 17 · (1 – e– 0,3 · Phyd ), 1 W ≤ Phyd ≤ 2 500 W\n“Reference power” means a relation between hydraulic power and power consumption of a circulator, taking into account the dependency between circulator efficiency and size.\n“Pref” means the reference power (in watts) of the circulator in a given head and flow.\n6.. Define the reference control curve as the straight line between the points:\n(Q 100 %, H 100 %) and (Q 0 %, H 100 % 2 )\n7.. Select a setting of the circulator ensuring that the circulator on the selected curve reaches Q · H = max point. For circulators integrated in products follow the reference control curve by adjusting the system curve and speed of the circulator.\n“System curve” means a relationship between flow and head (H = f(Q)) resulting from friction in the heating system or cooling distribution system, as presented in the following graph:\n8.. Measure P1 and H at the flows:\nQ100 % , 0,75 · Q100 % , 0,5 · Q100 % , 0,25 · Q100 %\n“P1 ” means the electrical power (in watts) consumed by the circulator at the specified point of operation.\n9.. Calculate PL as follows:\nP L = H ref H meas · P 1,meas , if Hmeas ≤ Href\nPL = P1,meas, if Hmeas > Href\nWhere Href is the head on the reference control curve at the different flows.\n10.. Using the measured values of PL and this load profile:\nFlow [%]\nTime [%]\n100\n6\n75\n15\n50\n35\n25\n44\nCalculate the weighted average power PL,avg as:\nPL,avg = 0,06 · PL, 100 % + 0,15 · PL, 75 % + 0,35 · PL, 50 % + 0,44 · PL, 25 %\nCalculate the energy efficiency index as:\nEEI = P L,avg P ref · C 20 % , where C 20 % = 0,49\nExcept for circulators integrated in products designed for primary circuits of thermal solar systems and for heat pumps, where the energy efficiency index is calculated as:\nEEI = P L,avg P ref · C 20 % · 1 – e – 3,8 · n s 30 1,36 where C20 % = 0,49 and n s is the specific speed defined as\nn s = n 100 % 60 · Q 100 % H 0,75 100 % where\nn s [rpm] is specific speed of a circulator;\nn100 % is rotational speed in rpm in this duty defined at Q 100 % and H 100 %. ’.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "CXX % means a scaling factor that ensures that at the time of defining the scaling factor only XX % of circulators of a certain type have an EEI ≤ 0,20.’."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2012/622/annex",
    "retrieved_at": "2026-11-01T14:49:19.644921+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}