Division Circumstances in which required
United Kingdom
Further testing shall be required where effects are seen following laboratory testing in accordance with the requirements set out in point 10.3.2.1 and where the relevant risk quotient analysis indicates a risk to the standard indicator non-target arthropod species.
Firstly, the indicator species affected in standard Tier 1 laboratory testing (point 10.3.2.1) shall be tested. In addition, where an in-field risk is indicated to one or both standard indicator species, testing of one additional species shall be required. Where an off-field risk to the standard indicator species is indicated, testing of one further additional species shall be required.
An aged residue study shall be conducted with the most sensitive species to give information on the time scale needed for potential re-colonisation of treated in-field areas.