# Commission Regulation (EU) No 617/2013 of 26 June 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for computers and computer servers (Text with EEA relevance), Division 4: INTERNAL POWER SUPPLY EFFICIENCY

Extent: E+W+S+N.I.

The model shall be considered to comply with the requirements set out in point 5 of Annex II if the test results do not exceed the respective verification tolerances given in the table below.
Verification tolerances for internal power supply efficiency
Requirements set out
Verification tolerances
The arithmetical mean of the efficiency at load conditions as defined in Annex II falls below the applicable requirements for average active efficiency.
The determined value shall not be lower than the declared value by more than 2 %.
The arithmetical mean of the power factor as defined in Annex II falls below the applicable requirements for the power factor.
The determined value shall not be lower than the declared value by more than 10 %.

---
Source: https://www.legislation.gov.uk/eur/2013/617/annex/III/division/4 (the official version)
Page: https://openlegislation.uk/eu-regulation-2013-617/annex-III/division-4
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.