Division 1 Specific Ecodesign requirements
United Kingdom
Vacuum cleaners shall comply with the following requirements:
- (a)
From 1 September 2014:
-
annual energy consumption shall be less than 62,0 kWh/year,
-
rated input power shall be less than 1 600 W,
-
dust pick up on carpet (dpuc ) shall be greater than or equal to 0,70. This limit shall not apply to hard floor vacuum cleaners,
-
dust pick up on hard floor (dpuhf ) shall be greater than or equal to 0,95. This limit shall not apply to carpet vacuum cleaners.
These limits shall not apply to water filter vacuum cleaners.
-
- (b)
From 1 September 2017:
-
annual energy consumption shall be less than 43,0 kWh/year,
-
rated input power shall be less than 900W,
-
dust pick up on carpet (dpuc ) shall be greater than or equal to 0,75. This limit shall not apply to hard floor vacuum cleaners,
-
dust pick up on hard floor (dpuhf ) shall be greater than or equal to 0,98. This limit shall not apply to carpet vacuum cleaners,
-
dust re-emission shall be no more than 1,00 %,
-
sound power level shall be less than or equal to 80 dB(A),
-
the hose, if any, shall be durable so that it is still useable after 40 000 oscillations under strain,
-
operational motor lifetime shall be greater than or equal to 500 hours.
-
The annual energy consumption, rated input power, dpuc (dust pick up on carpet), dpuhf (dust pick up on hard floor), dust re-emission, sound power level, durability of the hose and operational motor lifetime are measured and calculated in accordance with Annex II.