OpenLegislation

Division 4 Dust pick-up

United Kingdom

Original text. Later amendments are not shown.

The dust pick-up on hard floor (dpuhf ) shall be the determined as the average of the results of the two cleaning cycles in a hard floor test.

The dust pick-up on carpet (dpuc ) shall be the determined as the average of the results of the cleaning cycles in a carpet test. To correct for deviations from a test carpet’s original properties, the dust pick-up on carpet (dpuc ) shall be the calculated as follows:

dpu c = dpu m × dpu cal dpu ref

where:

  • dpum is the measured dust pick-up of the vacuum cleaner;

  • dpucal is the dust pick-up of the reference vacuum cleaner system measured when the test carpet was in original condition;

  • dpuref is the measured dust pick-up of the reference vacuum cleaner system.

Values of dpum for each of the cleaning cycles, dpuc, dpucal and dpuref shall be included in the technical documentation.