{
  "url": "https://openlegislation.uk/eu-regulation-2013-715/annex-I",
  "json_url": "https://openlegislation.uk/eu-regulation-2013-715/annex-I.json",
  "legislation": "eur/2013/715",
  "legislation_title": "Commission Regulation (EU) No 715/2013 of 25 July 2013 establishing criteria determining when copper scrap ceases to be waste under Directive 2008/98/EC of the European Parliament and of the Council",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2013-715",
  "path": "annex/I",
  "kind": "annex",
  "number": "I",
  "heading": null,
  "text": "Criteria for copper scrap\nOJ L 159, 29.6.1996, p. 1.\nOJ L 226, 6.9.2000, p. 3.\nOJ L 158, 30.4.2004, p. 7.\nOJ L 37, 13.2.2003, p. 24.\nOJ L 269, 21.10.2000, p. 34.\nCriteria\nSelf-monitoring requirements\nSection 1.Quality of copper scrap resulting from the recovery operation\n1.1.\nThe scrap shall be graded according to a customer specification or an industry specification or a standard for direct use in the production of metal substances or objects by smelters, refiners, re-melters or other metals producers.\nQualified staff shall grade each consignment.\n1.2.\nThe total amount of foreign materials shall be < 2 % by weight;\nForeign materials are:\nmetals other than copper and copper alloys,\nnon-metallic materials such as earth, dust, insulation and glass,\ncombustible non-metallic materials such as rubber, plastic, fabric, wood and other chemical or organic substances,\nslag, dross, skimming, baghouse dust, grinder dust, sludge.\nQualified staff shall carry out visual inspection of each consignment.\nAt appropriate intervals (at least every 6 months) representative samples of each grade of copper scrap shall be analysed to measure the total amount of foreign materials. The total amount of foreign materials shall be measured by weighing after separating copper/copper alloy metallic particles and objects from particles and objects consisting foreign materials by hand sorting or other means of separation (e.g. by magnet or based on the density).\nThe appropriate frequencies of analysing representative samples shall be established taking into account the following factors:\nthe expected pattern of variability (for example as shown by historical results),\nthe inherent risk of variability in the quality of the waste used as input for the recovery operation and in the performance of the treatment process,\nthe inherent precision of the monitoring method, and\nthe proximity of results to the limit values for the total amount of foreign materials.\nThe process of determining monitoring frequencies should be documented as part of the management system and should be available for auditing.\n1.3.\nThe scrap shall not contain excessive metal oxide in any form, except for typical amounts arising from outside storage of prepared scrap under normal atmospheric conditions.\nQualified staff shall carry out a visual inspection of each consignment.\n1.4.\nThe scrap shall be free of visible oil, oily emulsions, lubricants or grease except negligible amounts that will not lead to any dripping.\nQualified staff shall carry out a visual inspection of each consignment, paying particular attention to those parts where oil is most likely to drip.\n1.5.\nThere is no need for response action according to national or international rules on monitoring and response procedures for radioactive scrap metal.\n...\nQualified staff shall monitor the radioactivity of each consignment. Each consignment of scrap shall be accompanied by a certificate established in accordance with national or international rules on monitoring and response procedures for radioactive scrap metal. The certificate may be included in other documentation accompanying the consignment.\n1.6.\nThe scrap shall not display any of the hazardous properties listed in Annex III to Directive 2008/98/EC of the European Parliament and the Council. The scrap shall comply with the concentration limits laid down in Commission Decision 2000/532/EC and not exceed the concentration limits laid down in Annex IV to Regulation (EC) No 850/2004 of the European Parliament and the Council.\nProperties of alloy metals included in copper alloys are not relevant for this requirement.\nQualified staff shall investigate each consignment by visual inspection. Where visual inspection raises any suspicious of possible hazardous properties, further appropriate monitoring measures shall be taken, such as sampling and testing where appropriate. The staff shall be trained on potential hazardous properties that may be associated with copper scrap and on material components or features that allow recognising the hazardous properties. The procedure of recognising hazardous materials shall be documented under the management system.\n1.7.\nThe scrap does not contain any pressurised, closed or insufficiently open containers that could cause explosions in a metal work furnace.\nQualified staff shall investigate each consignment by visual inspection.\n1.8.\nThe scrap shall not contain PVC in form of coatings, paints, or residual plastics.\nQualified staff shall investigate each consignment by visual inspection.\nSection 2.Waste used as input for the recovery operation\n2.1.Only waste that contained recoverable copper or copper alloys may be used as input.\n2.2.Hazardous waste shall not be used as an input except where proof is provided that the processes and techniques specified under ‘criteria on treatment and techniques’ to remove all hazardous properties have been applied.\n2.3.The following wastes shall not be used as an input:\nfilings and turnings that contain fluids such as oil or oily emulsions, and\nbarrels and containers, except equipment from end-of-life vehicles, which contain or have contained oil or paints.\nAcceptance control of all waste received (by visual inspection) and of the accompanying documentation shall be carried out by qualified staff which is trained on how to recognise waste that does not fulfil the criteria set out in this section.\nSetion 3.Treatment processes and techniques\n3.1.The copper scrap shall have been segregated at source or while collecting or the input wastes shall have been treated to separate the copper scrap from the non-metal and non-copper metal components. The copper scrap resulting from these operations shall be kept separate from any other waste.\n3.2.All mechanical treatments (like cutting, shearing, shredding or granulating; sorting, separation, cleaning, de-polluting, emptying) needed to prepare the metal scrap for direct input into final use shall have been completed.\n3.3.For waste containing hazardous components the following specific requirements shall apply:\ninput materials that originate from waste electrical or electronic equipment or from end-of-life vehicles shall have undergone all treatments required by the EU-derived domestic legislation that transposed Article 6 of Directive 2000/53/EC of the European Parliament and of the Council on end-of life vehicles, as last amended by Commission Delegated Directive (EU) 2020/363, and Article 8 of Directive 2012/19/EU of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE), as last amended by Directive (EU) 2018/849,\nchlorofluorocarbons in discarded equipment shall have been captured in a process approved by the competent authorities,\ncables shall have been chopped or stripped. If a cable contains organic coatings (plastics), the organic coatings shall have been removed in accordance with best available techniques,\nbarrels and containers shall have been emptied and cleaned,\nhazardous substances in waste not mentioned in point (1) shall have been efficiently removed in a process which is approved by the competent authority.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Words in Annex 1 Table Section 1.5 omitted (31.12.2020) by virtue of The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 12(8)(a); 2020 c. 1, Sch. 5 para. 1(1)"
    },
    {
      "type": "F",
      "label": "F2",
      "text": "Words in Annex 1 Table Section.3.3 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 12(8)(b) (as amended by S.I. 2020/1540, regs. 1(3), 14(8)(d)); 2020 c. 1, Sch. 5 para. 1(1)"
    },
    {
      "type": "footnote",
      "label": "f1",
      "text": "OJ L 226, 6.9.2000, p. 3."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "OJ L 158, 30.4.2004, p. 7."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2013/715/annex/I",
    "retrieved_at": "2026-11-01T14:48:30.544063+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}