  "legislation_title": "Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2013-811",
  "path": "annex/III/division/10",
  "kind": "division",
  "number": "10",
  "heading": null,
  "text": "The design of the label for heat pump combination heaters shall be the following:\nWhereby:\n(a)The label shall be at least 105 mm wide and 200 mm high. Where the label is printed in a larger format, its content shall nevertheless remain proportionate to the specifications above.\n(b)The background shall be white.\n(c)Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 % cyan, 70 % magenta, 100 % yellow, 0 % black.\n(d)The label shall fulfil all of the following requirements (numbers refer to the figure above):\naEU label border stroke: 4 pt, colour: cyan 100 %, round corners: 3,5 mm.\nb UK flag: colours—\nthe blue background: 100,72,00,18.5;\nthe red crosses: 00,100,81,4\nthe remaining part: 100% white;\ncEnergy label: Colour: X-00-00-00. Pictogram as depicted: UK flag + energy label: width: 86 mm, height: 17 mm.\ndSub-logos border: 1 pt, colour: cyan 100 %, length: 86 mm.\neSpace heating function:\nPictogram as depicted.\nfWater heating function:\nPictogram as depicted, including the declared load profile expressed as the appropriate letter in accordance with Table 15 of Annex VII: Calibri bold 16 pt, 100 % black.\ngA++-G and A-G, A+++-D or A+-F scales, respectively:\nArrow: height: 5 mm, gap: 1,3 mm, colours:\nHighest class: X-00-X-00,\nSecond class: 70-00-X-00,\nThird class: 30-00-X-00,\nFourth class: 00-00-X-00,\nFifth class: 00-30-X-00,\nSixth class: 00-70-X-00,\nSeventh class: 00-X-X-00,\nEighth class: 00-X-X-00,\nLast class: 00-X-X-00,\nText: Calibri bold 14 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row;\nArrow: height: 7 mm, gap: 1 mm, colours:\nHighest class: X-00-X-00,\nSecond class: 70-00-X-00,\nThird class: 30-00-X-00,\nFourth class: 00-00-X-00,\nFifth class: 00-30-X-00,\nSixth class: 00-70-X-00,\nLast class: 00-X-X-00,\nText: Calibri bold 16 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row.\nhSeasonal space heating and water heating energy efficiency classes:\nArrow: width: 14 mm, height: 9 mm, 100 % black,\nText: Calibri bold 18 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row.\niRated heat output:\nBorder: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,\nValues ‘YZ’: Calibri at least 12 pt, 100 % black,\nText ‘kW’: Calibri regular 10 pt, 100 % black.\njEuropean temperature map and colour squares:\nPictogram as depicted,\nColours:\nDark blue: 86-51-00-00,\nMiddle blue: 53-08-00-00,\nLight blue: 25-00-02-00.\nkSound power level, indoors (if applicable) and outdoors:\nPictogram as depicted,\nBorder: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,\nValue ‘YZ’: Calibri bold 15 pt, 100 % black,\nText ‘dB’: Calibri regular 10 pt, 100 % black.\nlIf applicable, off-peak fitness:\nPictogram as depicted,\nBorder: 2 pt, colour: cyan 100 %, round corners: 3,5 mm.\nmYear of label introduction and number of Regulation:\nText: Calibri bold 10 pt.\nnSupplier’s name or trademark.\noSupplier’s model identifier:\nThe supplier’s name or trade mark and model identifier shall fit in a space of 86 × 12 mm.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Annex 3 para. 10: label image substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2020 (S.I. 2020/1528), reg. 1(4), Sch. 5 para. 8(15)"
    },
    {
      "type": "F",
      "label": "F2",
      "text": "Words in Annex 3 para. 10(d) substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2020 (S.I. 2020/1528), reg. 1(4), Sch. 5 para. 8(18)(a)"
    },
    {
      "type": "F",
      "label": "F3",
      "text": "Words in Annex 3 para. 10(d) substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2020 (S.I. 2020/1528), reg. 1(4), Sch. 5 para. 8(18)(b)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2013/811/annex/III/division/10",
    "retrieved_at": "2026-11-01T14:48:27.457901+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}