# Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device (Text with EEA relevance), Division 12: The design of the label for packages of combination heater, temperature control and solar device shall be the following:

Extent: E+W+S+N.I.

Whereby:
(a)The label shall be at least 210 mm wide and 297 mm high. Where the label is printed in a larger format, its content shall nevertheless remain proportionate to the specifications above.
(b)The background shall be white.
(c)Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 % cyan, 70 % magenta, 100 % yellow, 0 % black.
(d)The label shall fulfil all of the following requirements (numbers refer to the figure above):
aEU label border stroke: 6 pt, colour: cyan 100 %, round corners: 3,5 mm.
b UK flag: colours—
the blue background: 100,72,00,18.5;
the red crosses: 00,100,81,4
the remaining part: 100% white;
cEnergy label: Colour: X-00-00-00. Pictogram as depicted: UK flag + energy label: width: 191 mm, height: 37 mm.
dSub-logos border: 2 pt, colour: cyan 100 %, length: 191 mm.
eCombination heater:
Pictograms as depicted; for water heating function, including the declared load profile expressed as the appropriate letter in accordance with Table 15 of Annex VII: Calibri bold 16 pt, 100 % black.
Seasonal space heating and water heating energy efficiency class of combination heater:
Arrow: width: 19 mm, height: 11 mm, 100 % black,
Text: Calibri bold 23 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row,
Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
fPackage with solar collector, hot water storage tank, temperature control and/or supplementary heater:
Pictograms as depicted,
‘+’ symbol: Calibri bold 50 pt, cyan 100 %,
Boxes: width: 12 mm, height: 12 mm, border: 4 pt, cyan 100 %,
Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
gSpace heating function:
Pictogram as depicted.
hA+++-G scale with border:
Arrow: height: 6,5 mm, gap: 1 mm, colours:
Highest class: X-00-X-00,
Second class: 70-00-X-00,
Third class: 30-00-X-00,
Fourth class: 00-00-X-00,
Fifth class: 00-30-X-00,
Sixth class: 00-70-X-00,
Seventh class: 00-X-X-00,
If applicable, last classes: 00-X-X-00,
Text: Calibri bold 16 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row,
Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
iSeasonal space heating and water heating energy efficiency class, respectively, for package of combination heater, temperature control and solar device:
Arrow: width: 24 mm, height: 14 mm, 100 % black,
Text: Calibri bold 28 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row.
jWater heating function:
Pictogram as depicted, including the declared load profile expressed as the appropriate letter in accordance with Table 15 of Annex VII: Calibri bold 22 pt, 100 % black.
kYear of label introduction and number of Regulation:
Text: Calibri bold 12 pt.
lDealer’s and/or supplier's name or trademark.
mDealer’s and/or supplier's model identifier:
The dealer’s and/or supplier’s name or trade mark and model identifier shall fit in a space of 191 × 19 mm.

---