  "url": "https://openlegislation.uk/eu-regulation-2013-811/annex-V/division-4",
  "json_url": "https://openlegislation.uk/eu-regulation-2013-811/annex-V/division-4.json",
  "legislation": "eur/2013/811",
  "legislation_title": "Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2013-811",
  "path": "annex/V/division/4",
  "kind": "division",
  "number": "4",
  "heading": "SOLAR DEVICES",
  "text": "For solar devices, the technical documentation referred to in Article 3(4)(b) shall include:\n(a)the name and address of the supplier;\n(b)a description of the solar device model sufficient for its unambiguous identification;\n(c)where appropriate, the references of the designated standards applied;\n(d)where appropriate, the other technical standards and specifications used;\n(e)the identification and signature of the person empowered to bind the supplier;\n(f)technical parameters (for pumps in the collector loop if applicable):\nthe collector aperture area Asol in m2, to two decimal places;\nthe collector efficiency ηcol in %, rounded to the nearest integer;\nthe energy efficiency class of the solar hot water storage tank, determined in accordance with point 3 of Annex II;\nthe standing loss S of the solar hot water storage tank in W, rounded to the nearest integer;\nthe storage volume V of the solar hot water storage tank in litres and m3;\nthe annual non-solar heat contribution Qnonsol in kWh in terms of primary energy for electricity and/or in kWh in terms of GCV for fuels, for the load profiles M, L, XL and XXL under average climate conditions, rounded to the nearest integer;\nthe pump power consumption solpump in W, rounded to the nearest integer;\nthe standby power consumption solstandby in W, to two decimal places;\nthe annual auxiliary electricity consumption Qaux in kWh in terms of final energy, rounded to the nearest integer;\n(g)any specific precautions that shall be taken when the solar device is assembled, installed or maintained.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Word in Annex 5 s. 4(c) substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 5 para. 9(8); 2020 c. 1, Sch. 5 para. 1(1)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2013/811/annex/V/division/4",
    "retrieved_at": "2026-11-01T14:48:27.457901+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}