OpenLegislation

Division 2 ENERGY EFFICIENCY CLASSES OF HOT WATER STORAGE TANKS

United Kingdom

Original text. Later amendments are not shown.

The energy efficiency class of a hot water storage tank shall be determined on the basis of its standing loss as set out in Table 2.

Table 2

Energy efficiency classes of hot water storage tanks

Energy efficiency classStanding loss S in Watts, with storage volume V in litres
A+ S < 5,5 + 3,16 × V 0,4
A 5,5 + 3,16 × V 0,4 ≤ S < 8,5 + 4,25 × V 0,4
B 8,5 + 4,25 × V 0,4 ≤ S < 12 + 5,93 × V 0,4
C 12 + 5,93 × V 0,4 ≤ S < 16,66 + 8,33 × V 0,4
D 16,66 + 8,33 × V 0,4 ≤ S < 21 + 10,33 × V 0,4
E 21 + 10,33 × V 0,4 ≤ S < 26 + 13,66 × V 0,4
F 26 + 13,66 × V 0,4 ≤ S < 31 + 16,66 × V 0,4
G S > 31 + 16,66 × V 0,4