General conditions for testing water heaters:

  1. (a)

    measurements shall be carried out using the load profiles set out in Table 3;

  2. (b)

    measurements shall be carried out using a 24-hour measurement cycle as follows:

    • 00:00 to 06:59: no water draw-off,

    • from 07:00: water draw-offs according to the declared load profile,

    • from end of last water draw-off until 24:00: no water draw-off;

  3. (c)

    the declared load profile shall be the maximum load profile or the load profile one below the maximum load profile.

Table 3

Load profiles of water heaters

h3XSXXSXSS
Qtap f Tm Qtap f Tm Qtap f Tm Qtap f Tm Tp
kWhl/min°CkWhl/min°CkWhl/min°CkWhl/min°C°C
07:00 0,015 225 0,105 225 0,105 325
07:05 0,015 225
07:15 0,015 225
07:26 0,015 225
07:30 0,015 225 0,105 225 0,525 335 0,105 325
07:45
08:01
08:05
08:15
08:25
08:30 0,105 225 0,105 325
08:45
09:00 0,015 225
09:30 0,015 225 0,105 225 0,105 325
10:00
10:30
11:00
11:30 0,015 225 0,105 225 0,105 325
11:45 0,015 225 0,105 225 0,105 325
12:00 0,015 225 0,105 225
12:30 0,015 225 0,105 225
12:45 0,015 225 0,105 225 0,525 335 0,315 41055
14:30 0,015 225
15:00 0,015 225
15:30 0,015 225
16:00 0,015 225
16:30
17:00
18:00 0,105 225 0,105 325
18:15 0,105 225 0,105 340
18:30 0,015 225 0,105 225
19:00 0,015 225 0,105 225
19:30 0,015 225 0,105 225
20:00 0,105 225
20:30 1,05 335 0,42 41055
20:45 0,105 225
20:46
21:00 0,105 225
21:15 0,015 225 0,105 225
21:30 0,015 225 0,525 545
21:35 0,015 225 0,105 225
21:45 0,015 225 0,105 225
Qref 0,3452,12,12,1

Continued Table 3

Load profiles of water heaters

hMLXL
Qtap f Tm Tp Qtap f Tm Tp Qtap f Tm Tp
kWhl/min°C°CkWhl/min°C°CkWhl/min°C°C
07:00 0,105 325 0,105 325 0,105 325
07:05 1,4 640 1,4 640
07:15 1,82 640
07:26 0,105 325
07:30 0,105 325 0,105 325
07:45 0,105 325 4,42 101040
08:01 0,105 325 0,105 325
08:05 3,605 101040
08:15 0,105 325 0,105 325
08:25 0,105 325
08:30 0,105 325 0,105 325 0,105 325
08:45 0,105 325 0,105 325 0,105 325
09:00 0,105 325 0,105 325 0,105 325
09:30 0,105 325 0,105 325 0,105 325
10:00 0,105 325
10:30 0,105 31040 0,105 31040 0,105 31040
11:00 0,105 325
11:30 0,105 325 0,105 325 0,105 325
11:45 0,105 325 0,105 325 0,105 325
12:00
12:30
12:45 0,315 41055 0,315 41055 0,735 41055
14:30 0,105 325 0,105 325 0,105 325
15:00 0,105 325
15:30 0,105 325 0,105 325 0,105 325
16:00 0,105 325
16:30 0,105 325 0,105 325 0,105 325
17:00 0,105 325
18:00 0,105 325 0,105 325 0,105 325
18:15 0,105 340 0,105 340 0,105 340
18:30 0,105 340 0,105 340 0,105 340
19:00 0,105 325 0,105 325 0,105 325
19:30
20:00
20:30 0,735 41055 0,735 41055 0,735 41055
20:45
20:46 4,42 101040
21:00 3,605 101040
21:15 0,105 325 0,105 325
21:30 1,4 640 0,105 325 4,42 101040
21:35
21:45
Qref 5,84511,65519,07

Continued Table 3

Load profiles of water heaters

hXXL
Qtap f Tm Tp
kWhl/min°C°C
07:00 0,105 325
07:05
07:15 1,82 640
07:26 0,105 325
07:30
07:45 6,24 161040
08:01 0,105 325
08:05
08:15 0,105 325
08:25
08:30 0,105 325
08:45 0,105 325
09:00 0,105 325
09:30 0,105 325
10:00 0,105 325
10:30 0,105 31040
11:00 0,105 325
11:30 0,105 325
11:45 0,105 325
12:00
12:30
12:45 0,735 41055
14:30 0,105 325
15:00 0,105 325
15:30 0,105 325
16:00 0,105 325
16:30 0,105 325
17:00 0,105 325
18:00 0,105 325
18:15 0,105 340
18:30 0,105 340
19:00 0,105 325
19:30
20:00
20:30 0,735 41055
20:45
20:46 6,24 161040
21:00
21:15 0,105 325
21:30 6,24 161040
21:35
21:45
Qref 24,53