OpenLegislation

Division 9 Technical parameters of solar devices

United Kingdom

Original text. Later amendments are not shown.

The following parameters shall be established for solar devices:

  1. (a)

    the collector aperture area Asol in m2, rounded to two decimal places;

  2. (b)

    the zero-loss efficiency η0 , rounded to three decimal places;

  3. (c)

    the first-order coefficient a1 in W/(m2 K), rounded to two decimal places;

  4. (d)

    the second-order coefficient a2 in W/(m2 K2), rounded to three decimal places;

  5. (e)

    the incidence angle modifier IAM, rounded to two decimal place;

  6. (f)

    the pump power consumption solpump in W, rounded to two decimal places;

  7. (g)

    the standby power consumption, solstandby in W, rounded to two decimal places.