OpenLegislation

Division (a) Conventional water heaters and heat pump water heaters:

United Kingdom

Original text. Later amendments are not shown.

The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:

AEC = 0,6 × 366 × Q elec × 1 − SCF × smart + Q cor CC

The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:

AFC = 0,6 × 366 × Q fuel × 1 − SCF × smart + Q cor