Division 6 TECHNICAL PARAMETERS OF WATER HEATERS
United Kingdom
The following parameters shall be established for water heaters:
- (a)
the daily electricity consumption Qelec in kWh, rounded to three decimal places;
- (b)
the declared load profile, expressed by the appropriate letter in accordance with Table 1 of this Annex;
- (c)
the sound power level LWA , in dB, indoors, rounded to the nearest integer (for heat pump water heaters, if applicable);
in addition, for water heaters using fossil and/or biomass fuels:
- (d)
the daily fuel consumption Qfuel in kWh in terms of GCV, rounded to three decimal places;
- (e)
the emissions of nitrogen oxides, expressed in nitrogen dioxide, in mg/kWh fuel input in terms of GCV, rounded to the nearest integer;
in addition, for water heaters for which the value of smart is declared as being ‘1’:
- (f)
the weekly fuel consumption with smart controls Qfuel,week,smart in kWh in terms of GCV, rounded to three decimal places;
- (g)
the weekly electricity consumption with smart controls Qelec,week,smart in kWh, rounded to three decimal places;
- (h)
the weekly fuel consumption without smart controls Qfuel,week in kWh in terms of GCV, rounded to three decimal places;
- (i)
the weekly electricity consumption without smart controls Qelec,week in kWh, rounded to three decimal places;
in addition, for storage water heaters with declared load profiles 3XS, XXS and XS:
- (j)
the storage volume V in litres, rounded to one decimal place;
in addition, for storage water heaters with declared load profiles M, L, XL, XXL, 3XL and 4XL:
- (k)
the mixed water at 40 °C V40 in litres, rounded to the nearest integer;
in addition, for solar water heaters:
- (l)
the collector aperture area Asol in m2, rounded to two decimal places;
- (m)
the zero-loss efficiency η0 , rounded to three decimal places;
- (n)
the first-order coefficient a1 in W/(m2 K), rounded to two decimal places;
- (o)
the second-order coefficient a2 in W/(m2 K2), rounded to three decimal places;
- (p)
the incidence angle modifier IAM, rounded to two decimal places;
- (q)
the pump power consumption solpump in W, rounded to two decimal places;
- (r)
the standby power consumption solstandby in W, rounded to two decimal places;
in addition, for heat pump water heaters:
- (s)
the sound power level LWA in dB, outdoors, rounded to the nearest integer.