# Commission Regulation (EU) No 814/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water heaters and hot water storage tanks (Text with EEA relevance), Division (a): The smart control factor is calculated as follows:

Extent: E+W+S+N.I.

SCF = 1 − Q fuel,week,smart + CC × Q elec,week,smart Q fuel,week + CC × Q elec,week

---