OpenLegislation

Division Section 11: To be filled in by undertakings having placed on the market gases contained in products or equipment pursuant to Article 19(4) of Regulation 517/2014 — Article 19(4) of Regulation (EU) No 517/2014 and point 6 of Annex VII to Regulation (EU) No 517/2014

United Kingdom

Original text. Later amendments are not shown.

Applicable for the first time to reporting on activities carried out in 2014 (by 31 March 2015 at the latest).

Quantities of fluorinated greenhouse gases listed in Annex I or Annex II to Regulation (EU) No 517/2014 or mixtures containing at least one of those gases contained in the products and equipment shall be reported in metric tonnes with accuracy to the third decimal place, by category. In addition to the total quantity of gases, the number of units shall be reported per category, unless otherwise stated.

Producers of products or equipment manufactured in F1Great Britain shall not report on products and equipment where the contained gases were previously imported into or produced in Great Britain. Where a producer itself produces bulk gas in Great Britain for use in Great Britain for manufacturing their products and equipment, its reporting on production (reporting section 1) would similarly cover the relevant gas amounts, so these amounts shall also not be reported in this section.

Importers of products or equipment containing a fluorinated greenhouse gas listed in Annex I or II to Regulation (EU) No 517/2014 shall report on all gas containing imports released by customs for free circulation in Great Britain. Imports of pre-blended polyols are not to be reported in this section but in section 2. Where hydrofluorocarbons (gases listed in Section 1 of Annex I to Regulation (EU) No 517/2014 or mixture containing at least one of those gases) contained in imported refrigeration, air conditioning or heat pump equipment had previously been exported from Great Britain, and had been subject to the hydrofluorocarbon quota limitation for placing on the market, that shall be reported in reporting section 12 in order to prove compliance with Article 14 of Regulation (EU) No 517/2014.

The categories of products or equipment listed below include components intended for the specified product or equipment categories.

The term ‘direct design’ refers in particular to air-to-air, water-to-air, brine-to-air systems; the term ‘indirect design’ in particular to air-to-water, water-to-water, brine-to-water systems, including hydronic heat-pumps.

AUTOMATICALLY CALCULATED QUANTITIESCOMMENTS
11AStationary equipment for comfort cooling or heating11A = 11A1 + 11A2 + 11A3 + 11A4 + 11A5 + 11A6 + 11A7 + 11A8 + 11A9 + 11A10 + 11A11 + 11A12 + 11A13 + 11A14
INFORMATION TO BE REPORTED
11A1Stationary equipment for comfort cooling/heating, direct design: Standalone/monobloc units of moveable type
11A2Stationary equipment for comfort cooling/heating, direct design: standalone/monobloc units of rooftop type
11A3Stationary equipment for comfort cooling/heating, direct design: standalone/monobloc units of other typeThe equipment type/s shall be specified.
11A4Stationary equipment for comfort cooling/heating, direct design: single split units charged with 3 kilograms or more of refrigerant
11A5Stationary equipment for comfort cooling/heating, direct design: single split units charged with less than 3 kilograms of refrigerant
11A6Stationary equipment for comfort cooling/heating, direct design: multi split units
11A7Stationary equipment for comfort cooling/heating, indirect design: standalone/monobloc units for domestic use
11A8Stationary equipment for comfort cooling/heating, indirect design: standalone/monobloc units for commercial or industrial use
11A9Stationary equipment for comfort cooling/heating, indirect design: standalone/monobloc units for other useThe intended use/s shall be specified.
11A10Stationary equipment for comfort cooling/heating, indirect design: split units for domestic use
11A11Stationary equipment for comfort cooling/heating, indirect design: split units for commercial or industrial use
11A12Stationary equipment for comfort cooling/heating, indirect design: split units for other useThe intended use/s shall be specified.
11A13Stationary equipment for comfort cooling/heating, both direct and indirect: standalone/monobloc units
11A14Stationary equipment for comfort cooling/heating, both direct and indirect: split units
AUTOMATICALLY CALCULATED QUANTITIES
11BStationary equipment for refrigeration11B = 11B1 + 11B2 + 11B3 + 11B4 + 11B5 + 11B6 + 11B7 + 11B8 + 11B9 + 11B10 + 11B11 + 11B12 + 11B13 + 11B14
INFORMATION TO BE REPORTED
11B1Stationary equipment for refrigeration, direct design: standalone/monobloc units for domestic use
11B2Stationary equipment for refrigeration, direct design: standalone/monobloc units for commercial or industrial use
11B3Stationary equipment for refrigeration, direct design: standalone/monobloc units for other useThe intended use/s shall be specified.
11B4Stationary equipment for refrigeration, direct design: split units for commercial or industrial use
11B5Stationary equipment for refrigeration, direct design: split units for other useThe intended use/s shall be specified.
11B6Stationary equipment for refrigeration, indirect design: standalone/monobloc units for commercial or industrial use
11B7Stationary equipment for refrigeration, indirect design: standalone/monobloc units for other useThe intended use/s shall be specified.
11B8Stationary equipment for refrigeration, indirect design: split units for commercial or industrial use
11B9Stationary equipment for refrigeration in indirect design: split units for other useThe intended use/s shall be specified.
11B10Stationary equipment for refrigeration, both direct and indirect: standalone/monobloc units
11B11Stationary equipment for refrigeration, both direct and indirect: split units
11B12Stationary equipment for process cooling or heating in direct design
11B13Stationary equipment for process cooling or heating in indirect design
11B14Stationary equipment for process cooling or heating, both direct and indirect
11CHeat pump tumble dryers
AUTOMATICALLY CALCULATED QUANTITIES
11DStationary heating/air conditioning including heatpumps as well as refrigeration (HACR) equipment for any other purposes11D = 11D1 + 11D2 + 11D3
INFORMATION TO BE REPORTED
11D1Stationary HACR equipment for any other purposes, direct designThe equipment type/s and purpose/s shall be specified.
11D2Stationary HACR equipment for any other purposes, indirect designThe equipment type/s and purpose/s shall be specified.
11D3Stationary HACR equipment for any other purposes, both direct and indirectThe equipment type/s and purpose/s shall be specified.
AUTOMATICALLY CALCULATED QUANTITIES
11EMobile refrigeration equipment11E = 11E1 + 11E2 + 11E3 + 11E4
INFORMATION TO BE REPORTED
11E1Mobile refrigeration equipment for refrigerated light duty vehicles (e.g. vans)
11E2Mobile refrigeration equipment for refrigerated heavy duty vehicles (including trucks and trailers)
11E3Mobile refrigeration equipment for refrigerated ships
11E4Any other mobile refrigeration equipmentThe equipment type/s shall be specified.
AUTOMATICALLY CALCULATED QUANTITIES
11FMobile air conditioning equipment11F = 11F1 + 11F2 + 11F3 + 11F4 + 11F5 + 11F6 + 11F7 + 11F8 + 11F9
INFORMATION TO BE REPORTED
11F1Mobile air conditioning equipment for passenger cars
11F2Mobile air conditioning equipment for buses
11F3Mobile air conditioning equipment for vans (light duty vehicles)
11F4Mobile air conditioning equipment for trucks and trailers (heavy duty vehicles)
11F5Mobile air conditioning equipment for agricultural, forestry and construction vehicles and machinery
11F6Mobile air conditioning equipment for rail vehicles
11F7Mobile air conditioning equipment for ships
11F8Mobile air conditioning equipment for aircrafts and helicopters
11F9Any other mobile air conditioning equipmentThe equipment type/s shall be specified.
AUTOMATICALLY CALCULATED VALUE
11GTotal refrigeration, air conditioning or heat pump equipment11G = 11A + 11B + 11C + 11D + 11E + 11F
11HFoam products11H = 11H1 + 11H2 + 11H3 + 11H4
INFORMATION TO BE REPORTED
11H1Extruded polystyrene (XPS) insulation boardsQuantities of XPS boards shall be reported in units of cubic metres (next to quantities of contained fluorinated gases in units of metric tonnes)
11H2Polyurethane (PU) insulation boardsQuantities of PU boards shall be reported in units of cubic metres (next to quantities of contained fluorinated gases in units of metric tonnes)
11H3One component foam (OCF)The measurement unit can be pieces of OCF cans (next to quantities of contained fluorinated gases in units of metric tonnes)
11H4Other foam products

The product category/ies shall be specified.

Imports of pre-blended polyols (e.g. in foam systems/containers) shall not be reported here but rather in section 2.

Quantities of foam products shall be reported in units of either cubic metres, metric tonnes, or pieces of product/equipment (next to quantities of contained fluorinated gases in units of metric tonnes)

11IFire protection equipment (including systems incorporated in vehicles)
11JMedical or pharmaceutical aerosols
11KNon-medical aerosols
11LMedical equipment (without aerosols)
11MSwitch gear for transmission and distribution of electricity
11NOther electrical transmission and distribution equipment
11OParticle accelerators
11POther products and equipment containing gases listed in Annex I or Annex II of Regulation (EU) No 517/2014

The product or equipment category/ies shall be specified.

The measurement unit can be either volume, weight or pieces of product/equipment.

(next to quantities of contained fluorinated gases in units of metric tonnes)

AUTOMATICALLY CALCULATED QUANTITIES
11QTotal of products and equipment containing fluorinates gases listed in Annex I or Annex II of Regulation (EU) No 517/201411Q = 11G + 11H + 11I + 11J + 11K + 11L + 11M + 11N + 11O + 11P

Annotations

Textual amendments

F1

Words in Annex substituted (31.12.2020) by The Ozone-Depleting Substances and Fluorinated Greenhouse Gases (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/583), reg. 66(4)(a) (as substituted by The Ozone-Depleting Substances and Fluorinated Greenhouse Gases (Amendment etc.) (EU Exit) Regulations 2020 (S.I. 2020/1616), regs. 1(2), 2(32))