Mounted in accordance with EN ISO 9239-1, on a substrate of at least Class D-s2, d0 with minimum density of 400 kg/m3 or with an air gap (minimum height 30 mm) underneath.
An interlayer of at least Class Efl and with maximum thickness 3 mm and minimum density of 280 kg/m3 may be included.
Class as set out in Table 2 of the Annex to Decision 2000/147/EC.
Without surface coatings.
Conditioned in accordance with EN 13238 (50 % RH, 23 °C).
Substrate at least Class D-s2, d0.
Applies also to steps of stairs.
Product
Product detail
Minimum mean density(kg/m3)
Minimum overall thickness(mm)
End use condition
Class for floorings
Wood flooring
Solid wood flooring of pine or spruce
Pine: 480
Spruce: 400
14
Without air gap underneath
Dfl-s1
Wood flooring
Solid flooring of beech, oak, pine or spruce
Beech: 700
Oak: 700
Pine: 430
Spruce: 400
20
With or without air gap underneath
Dfl-s1
Wood parquet
Solid wood (one layer) parquet of walnut
650
8
Glued to substrate
Dfl-s1
Wood parquet
Solid (one layer) parquet of oak, maple or ash
Ash: 650
Maple: 650
Oak: 720
8
Glued to substrate
Dfl-s1
Wood parquet
Multilayer parquet with oak top layer, at least 3,5 mm
550
15
Without air gap underneath
Dfl-s1
Wood flooring and parquet
Solid wood flooring and parquet not specified above
400
6
All
Efl

---