# Commission Regulation (EU) No 1301/2014 of 18 November 2014 on the technical specifications for interoperability relating to the ‘energy’ subsystem of the rail system in the Union (Text with EEA relevance) (revoked), Division 4.2.9.1: Contact wire height

Extent: E+W+S+N.I.
Status: repealed

(1)The permissible data for contact wire height is given in Table 4.2.9.1.
(2)For the relation between the contact wire heights and pantograph working heights see EN 50119:2009 figure 1.
(3)At level crossings the contact wire height shall be specified by national rules or in the absence of national rules, according to EN 50122-1:2011, clauses 5.2.4 and 5.2.5.
(4)For the track gauge system 1 520 and 1 524 mm the values for contact wire height are as follows:
(a)Nominal contact wire height: between 6 000 mm and 6 300 mm;
(b)Minimum design contact wire height: 5 550 mm;
(c)Maximum design contact wire height: 6 800 mm.

---
Source: https://www.legislation.gov.uk/eur/2014/1301/annex/division/4/division/4.2/division/4.2.9/division/4.2.9.1 (the official version)