  • Power consumption in ‘off mode’: the power consumption in any off-mode condition shall not exceed 0,50 W.

  • Power consumption in ‘standby mode(s)’: the power consumption in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 0,50 W.

    The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display shall not exceed 1,00 W.

  • Power management: when domestic range hoods are not providing the main function, or when other energy-using product(s) are not dependent on its functions, equipment shall, unless inappropriate for the intended use, offer a power management function, or a similar function, that switches equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into:

    • ‘standby mode’, or

    • ‘off mode’, or

    • another condition which does not exceed the applicable power consumption requirements for ‘off mode’ and/or ‘standby mode’ when the equipment is connected to the mains power source.

  • The power management function shall be activated before delivery.

  • For range hoods with automatic functioning mode during the cooking period and fully automatic range hoods, the delay time after which the product switches automatically into the modes and conditions as referred to in the previous point shall be one minute after the motor and lighting have both been switched off either automatically or manually.