OpenLegislation

Division 3.3.1 Domestic range hoods with a maximum air flow in any of the available setting higher than 650 m3/h shall automatically revert to an air flow lower than or equal to 650 m3/h in a time tlimit. This is the time limit to extract a volume of air of 100 m3 by the domestic range hood operating with an airflow higher than 650 m3/h, before automatically switching to an airflow of 650 m3/h or lower. It is calculated, expressed in minutes and rounded to the nearest integer as:

United Kingdom

Original text. Later amendments are not shown.

tlimit=6000 m3Qmaxf1

Where:

  • Qmax is the maximum air flow of the domestic range hood, including intensive/boost mode if present, in m3/h and rounded to the first decimal place.

The mere presence of a manual switch or setting decreasing the air flow of the appliance to a value lower than or equal to 650 m3/h is not considered fulfilling this requirement.

Annotations

Footnotes

f1

See V = ∫ 0 t Q max 60 × dt which can be simplified to t limit = V max Q max × 60

Where:

  • Vmax is the maximum volume of air to be extracted, set at 100 m3,

  • Qmax is the maximum air flow of the range hood, including intensive/boost mode if present,

  • t is the time expressed in minutes and rounded to the nearest integer,

  • dt is the total time until the air volume of 100 m3 has been reached,

  • tlimit is the time limit, expressed in minutes and rounded to the nearest integer, needed to extract 100 m3.

Notes on Annex II

Textual amendments

F1

Words in Annex 2 substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 21(7); 2020 c. 1, Sch. 5 para. 1(1)