# Commission Regulation (EU) 2015/1095 of 5 May 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for professional refrigerated storage cabinets, blast cabinets, condensing units and process chillers (Text with EEA relevance), Annex III: Method for calculating the energy efficiency index for professional refrigerated storage cabinets

Extent: E+W+S+N.I.

For the calculation of the energy efficiency index (EEI) of a professional refrigerated storage cabinet model, the annual energy consumption of the cabinet is compared to its standard annual energy consumption.
The EEI is calculated as:
EEI = (AEC/SAEC) × 100
Where:
AEC = E24h × af × 365
AEC annual energy consumption of the cabinet in kWh/year
E24h energy consumption of the cabinet over 24 hours
af adjustment factor to be applied only for light-duty cabinets, according to Annex IV, point 2(b)
SAEC = M × Vn + N
SAEC standard annual energy consumption of the cabinet in kWh/year
Vn net volume of the appliance, which is the sum of net volumes of all compartments of the cabinet, expressed in litres.
M and N are given in the Table 2.
Table 2
M and N coefficient values
Category
Value for M
Value for N
Vertical Chilled
1,643
609
Vertical Frozen
4,928
1 472
Counter Chilled
2,555
1 790
Counter Frozen
5,840
2 380

---
Source: https://www.legislation.gov.uk/eur/2015/1095/annex/III (the official version)