  "url": "https://openlegislation.uk/eu-regulation-2015-1095/annex-V/division-2",
  "json_url": "https://openlegislation.uk/eu-regulation-2015-1095/annex-V/division-2.json",
  "legislation": "eur/2015/1095",
  "legislation_title": "Commission Regulation (EU) 2015/1095 of 5 May 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for professional refrigerated storage cabinets, blast cabinets, condensing units and process chillers (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2015-1095",
  "path": "annex/V/division/2",
  "kind": "division",
  "number": "2",
  "heading": "REQUIREMENTS FOR PRODUCT INFORMATION",
  "text": "From 1 July 2016, the following product information on condensing units shall be provided:\n(a) the instruction manuals for installers and end-users, and free access websites of manufacturers, their authorised representatives and importers, shall contain the following elements:\n(i) intended evaporating temperature, expressed in degrees Celsius (medium temperature – 10 °C, low temperature – 35 °C);\n(ii) for condensing units with a rated cooling capacity lower than 5kW and 2kW for medium and low temperatures respectively:\nthe rated COP, at full load and 32 °C ambient temperature, rounded to two decimal places, and rated cooling capacity and power input, expressed in kW and rounded to two decimal places;\nthe COP value, at full load and 25 °C ambient temperature, rounded to two decimal places, and corresponding cooling capacity and power input, expressed in kW and rounded to two decimal places;\n(iii) for condensing units with a rated cooling capacity higher than 5kW and 2kW for medium and low operating temperatures respectively:\nthe SEPR value, rounded to two decimal places;\nthe annual electricity consumption, expressed in kWh per year;\nthe rated cooling capacity, rated power input and rated COP;\nthe declared cooling capacity and declared power input, expressed in kW and rounded to three decimal places, and the COP value, rounded to two decimal places, at rating points B, C and D;\n(iv) for condensing units intended for use at ambient temperature above 35 °C, the COP value, at full load and 43 °C ambient temperature, rounded to two decimal places, and corresponding cooling capacity and power input, expressed in kW and rounded to two decimal places;\n(v) the type(s) and name(s) of refrigerant fluid(s) intended to be used with the condensing unit;\n(vi) any specific precautions that are to be taken when the condensing unit is maintained;\n(vii) any specific precautions that are to be taken to optimise the efficiency of the condensing unit when it is integrated into a refrigerating appliance;\n(viii) information relevant for recycling or disposal at end-of-life.\n(b) a section of the free access websites of manufacturers for installers and other professionals, their authorised representatives, or importers shall be provided, containing information relevant for:\n(i) installation in order to optimise energy efficiency of the appliances;\n(ii) non-destructive disassembly for maintenance purposes;\n(iii) disassembly and dismantling for disposal at end-of life.\n(c) the technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:\n(i) the elements specified in point (a);\n(ii) where the information relating to a specific model has been obtained by calculation on the basis of design or extrapolation from other combinations, the details of such calculations or extrapolations, and of any tests undertaken to verify the accuracy of the calculations, including details of the mathematical model for calculating the performance of such combinations and details of the measurements taken to verify that model.\nTables 4 and 5 below provide an indicative layout for the requested information\nTable 4\nInformation requirements for condensing units with a rated cooling capacity lower than 5kW and 2kW for medium and low operating temperatures respectively\nFor condensing units intended to operate at only one evaporating temperature, one of the two columns related to ‘Value’ can be deleted.\nModel(s): [information identifying the model(s) to which the information relates]\nRefrigerant fluid(s): [information to identify the refrigerant fluid(s) intended to be used with the condensing unit]\nItem\nSymbol\nValue\nUnit\nEvaporating temperature\nt\n– 10 °C\n– 35 °C\n°C\nParameters at full load and ambient temperature 32 °C\nRated cooling capacity\nPA\nx,xxx\nx,xxx\nkW\nRated power input\nDA\nx,xxx\nx,xxx\nkW\nRated COP\nCOPA\nx,xx\nx,xx\nParameters at full load and ambient temperature 25 °C\nCooling capacity\nP2\nx,xxx\nx,xxx\nkW\nPower input\nD2\nx,xxx\nx,xxx\nkW\nCOP\nCOP2\nx,xx\nx,xx\nParameters at full load and ambient temperature 43 °C (where applicable)\nCooling capacity\nP3\nx,xxx\nx,xxx\nkW\nPower input\nD3\nx,xxx\nx,xxx\nkW\nCOP\nCOP3\nx,xx\nx,xx\nOther items\nCapacity control\nfixed/step/variable\nContact details\nName and address of the manufacturer or its authorised representative.\nTable 5\nInformation requirements for condensing units with a rated cooling capacity higher than 5kW and 2kW for medium and low operating temperatures respectively\nFor condensing units intended to operate at only one evaporating temperature, one of the two columns related to ‘Value’ can be deleted.\nModel(s): [information identifying the model(s) to which the information relates]\nRefrigerant fluid(s): [information to identify the refrigerant fluid(s) intended to be used with the condensing unit]\nItem\nSymbol\nValue\nUnit\nEvaporating temperature\nt\n– 10 °C\n– 35 °C\n°C\nAnnual electricity consumption\nQ\nx\nx\nkWh/a\nSeasonal energy performance ratio\nSEPR\nx,xx\nx,xx\nParameters at full load and ambient temperature 32 °C (point (A)\nRated cooling capacity\nPA\nx,xx\nx,xx\nkW\nRated power input\nDA\nx,xx\nx,xx\nkW\nRated COP\nCOPA\nx,xx\nx,xx\nParameters at part load and ambient temperature 25 °C (point (B)\nDeclared cooling capacity\nPB\nx,xx\nx,xx\nkW\nDeclared power input\nDB\nx,xx\nx,xx\nkW\nDeclared COP\nCOPB\nx,xx\nx,xx\nParameters at part load and ambient temperature 15 °C (point (C)\nDeclared cooling capacity\nPc\nx,xx\nx,xx\nkW\nDeclared power input\nDc\nx,xx\nx,xx\nkW\nDeclared COP\nCOPC\nx,xx\nx,xx\nParameters at part load and ambient temperature 5 °C (point (D)\nDeclared cooling capacity\nPD\nx,xx\nx,xx\nkW\nDeclared power input\nDD\nx,xx\nx,xx\nkW\nDeclared COP\nCOPD\nx,xx\nx,xx\nParameters at full load and ambient temperature 43 °C (where applicable)\nCooling capacity\nP3\nx,xx\nx,xx\nkW\nPower input\nD3\nx,xx\nx,xx\nkW\nDeclared COP\nCOP3\nx,xx\nx,xx\nOther items\nCapacity control\nfixed/step/variable\nDegradation coefficient for fixed and staged capacity units\nCdc\n0,25\nContact details\nName and address of the manufacturer or its authorised representative.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "For condensing units intended to operate at only one evaporating temperature, one of the two columns related to ‘Value’ can be deleted."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "For condensing units intended to operate at only one evaporating temperature, one of the two columns related to ‘Value’ can be deleted."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2015/1095/annex/V/division/2",
    "retrieved_at": "2026-11-01T14:46:36.007402+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}