For local space heaters, the technical documentation referred to in Article 3(1)(e) and Article 3(2)(e) shall include:
(a)the name and address of the supplier;
(b)the model identifier;
(c)where appropriate, the references of the designated standards applied;
(d)where the preferred fuel is other woody biomass, non-woody biomass, other fossil fuel or other blend of biomass and fossil fuel as referred to in Table 2, a description of the fuel sufficient for its unambiguous identification and the technical standard or specification of the fuel, including the measured moisture content and the measured ash content, and for other fossil fuel also the measured volatile content of the fuel;
(e)where appropriate, the other technical standards and specifications used;
(f)the identification and signature of the person empowered to bind the supplier;
(g)the information included in Table 2 (for solid fuel local space heaters) and Table 3 (for gaseous/liquid fuel local space heaters), measured and calculated in accordance with Annex VIII;
(h)reports of tests undertaken by suppliers or on their behalf, including the name and address of the body that conducted the tests;
(i)any specific precautions that shall be taken when the local space heater is assembled, installed or maintained;
(j)a list of equivalent models, if applicable.
This information may be merged with the technical documentation provided in accordance with measures under Directive 2009/125/EC of the European Parliament and of the Council or measures listed in paragraph 4 of Schedule 1 to the Ecodesign for Energy-Related Products Regulations 2010.
Table 2
Technical parameters for solid fuel local space heaters
Model identifier(s):
Indirect heating functionality:[yes/no]
Direct heat output: …(kW)
Indirect heat output: …(kW)
Fuel
Preferred fuel (only one):
Other suitable fuel(s):
Wood logs with moisture content ≤ 25 %
[yes/no]
[yes/no]
Compressed wood with moisture content < 12 %
[yes/no]
[yes/no]
Other woody biomass
[yes/no]
[yes/no]
Non-woody biomass
[yes/no]
[yes/no]
Anthracite and dry steam coal
[yes/no]
[yes/no]
Hard coke
[yes/no]
[yes/no]
Low temperature coke
[yes/no]
[yes/no]
Bituminous coal
[yes/no]
[yes/no]
Lignite briquettes
[yes/no]
[yes/no]
Peat briquettes
[yes/no]
[yes/no]
Blended fossil fuel briquettes
[yes/no]
[yes/no]
Other fossil fuel
[yes/no]
[yes/no]
Blended biomass and fossil fuel briquettes
[yes/no]
[yes/no]
Other blend of biomass and solid fuel
[yes/no]
[yes/no]
Characteristics when operating with the preferred fuel
Seasonal space heating energy efficiency η s [%]:
Energy Efficiency Index (EEI):
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Heat output
Useful efficiency (NCV as received)
Nominal heat output
Pnom
x,x
kW
Useful efficiency at nominal heat output
ηth,nom
x,x
%
Minimum heat output (indicative)
Pmin
[x,x/N.A.]
kW
Useful efficiency at minimum heat output (indicative)
ηth,min
[x,x/N.A.]
%
Auxiliary electricity consumption
Type of heat output/room temperature control
(select one)
At nominal heat output
elmax
x,xxx
kW
single stage heat output, no room temperature control
[yes/no]
At minimum heat output
elmin
x,xxx
kW
two or more manual stages, no room temperature control
[yes/no]
In standby mode
elSB
x,xxx
kW
with mechanic thermostat room temperature control
[yes/no]
with electronic room temperature control
[yes/no]
with electronic room temperature control plus day timer
[yes/no]
with electronic room temperature control plus week timer
[yes/no]
Other control options (multiple selections possible)
room temperature control, with presence detection
[yes/no]
room temperature control, with open window detection
[yes/no]
with distance control option
[yes/no]
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable)
Ppilot
[x,xxx/N.A.]
kW
Contact details
Name and address of the supplier
Table 3
Technical parameters for gaseous/liquid fuel local space heaters
Model identifier(s):
Indirect heating functionality:[yes/no]
Direct heat output: …(kW)
Indirect heat output: …(kW)
Fuel
Select fuel type
[gaseous/liquid]
[specify]
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Heat output
Useful efficiency (NCV)
Nominal heat output
Pnom
x,x
kW
Useful efficiency at nominal heat output
ηth,nom
x,x
%
Minimum heat output (indicative)
Pmin
[x,x/N.A.]
kW
Useful efficiency at minimum heat output (indicative)
ηth,min
[x,x/N.A.]
%
Auxiliary electricity consumption
Type of heat output/room temperature control
(select one)
At nominal heat output
elmax
x,xxx
kW
single stage heat output, no room temperature control
[yes/no]
At minimum heat output
elmin
x,xxx
kW
two or more manual stages, no room temperature control
[yes/no]
In standby mode
elSB
x,xxx
kW
with mechanic thermostat room temperature control
[yes/no]
with electronic room temperature control
[yes/no]
with electronic room temperature control plus day timer
[yes/no]
with electronic room temperature control plus week timer
[yes/no]
Other control options (multiple selections possible)
room temperature control, with presence detection
[yes/no]
room temperature control, with open window detection
[yes/no]
Permanent pilot flame power requirement
with distance control option
[yes/no]
Pilot flame power requirement (if applicable)
Ppilot
[x,xxx/N.A.]
kW
Contact details
Name and address of the supplier

---
Source: https://www.legislation.gov.uk/eur/2015/1186/annex/V (the official version)