Division 1 The Energy Efficiency Index (EEI) of solid fuel boilers shall be calculated for the preferred fuel and rounded to the nearest integer as:
United Kingdom
EEI = ηson × 100 × BLF – F(1) – F(2) × 100 + F(3) × 100
where:
- (a)
ηson is the seasonal space heating energy efficiency in active mode, calculated as set out in point 4(b) of Annex VIII;
- (b)
BLF is the biomass label factor, which is 1,45 for biomass boilers and 1 for fossil fuel boilers;
- (c)
F(1) accounts for a negative contribution to the energy efficiency index due to adjusted contributions of temperature controls; F(1) = 3;
- (d)
F(2) accounts for a negative contribution to the energy efficiency index by auxiliary electricity consumption, and is calculated as set out in point 4(c) of Annex VIII;
- (e)
F(3) accounts for a positive contribution to the energy efficiency index by the electrical efficiency of solid fuel cogeneration boilers, and is calculated as follows:
F(3) = 2,5 × ηel,n