  "url": "https://openlegislation.uk/eu-regulation-2015-1188/annex-I",
  "json_url": "https://openlegislation.uk/eu-regulation-2015-1188/annex-I.json",
  "legislation": "eur/2015/1188",
  "legislation_title": "Commission Regulation (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local space heaters (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2015-1188",
  "path": "annex/I",
  "kind": "annex",
  "number": "I",
  "heading": "Definitions applicable for Annexes II to V",
  "text": "For the purpose of Annexes II to V the following definitions shall apply:\n(1)‘seasonal space heating energy efficiency’ (ηs) means the ratio between the space heating demand, supplied by a local space heater and the annual energy consumption required to meet this demand, expressed in %;\n(2)‘conversion coefficient’ (CC) means a coefficient the value of which is CC = 2.5;\n(3)‘nitrogen oxides emissions’ means the emissions of nitrogen oxides at nominal heat output expressed in mg/kWhinput based on GCV for gaseous or liquid fuel local space heaters and commercial local space heaters;\n(4)‘net calorific value’ (NCV) means the total amount of heat released by a unit quantity of fuel containing the appropriate moisture of the fuel, when it is burned completely with oxygen, and when the products of combustion are not returned to ambient temperature;\n(5)‘gross calorific value moisture free’ (GCV) means the total amount of heat released by a unit quantity of fuel dried of inherent moisture, when it is burned completely with oxygen, and when the products of combustion are returned to ambient temperature; this quantity includes the condensation heat of the water vapour formed by the combustion of any hydrogen contained in the fuel;\n(6)‘useful efficiency, at either nominal or minimum heat output’, (ηth,nom or ηth,min respectively) means the ratio of the useful heat output and the total energy input of a local space heater, expressed in %, whereby:\n(a)for domestic local space heaters the total energy input is expressed in terms of NCV and/or in terms of final energy multiplied by CC;\n(b)for commercial local space heaters the total energy input is expressed in terms of GCV and in terms of final energy multiplied by CC;\n(7)‘electric power requirement at nominal heat output’ (elmax) means the electric power consumption of the local space heater while providing the nominal heat output. The electric power consumption shall be established without consideration of the power consumption of a circulator in case the product offers indirect heating functionality and a circulator is incorporated, expressed in kW;\n(8)‘electric power requirement at minimum heat output’ (elmin) means the electric power consumption of the local space heater while providing the minimum heat output. The electric power consumption shall be established without consideration of the power consumption of a circulator in case the product offers indirect heating functionality and a circulator is incorporated, expressed in kW;\n(9)‘electric power requirement in standby mode’ (elsb) means the electric power consumption of the product while in standby mode, expressed in kW;\n(10)‘permanent pilot flame power requirement’ (Ppilot) means the fuel consumption of gaseous or liquid fuel of the product for the provision of a flame to serve as an ignition source for the more powerful combustion process needed for nominal or part load heat output, when lit for more than 5 minutes before the main burner is on, expressed in kW;\n(11)‘manual heat charge control, with integrated thermostat’ means a manually operated sensing device integrated into the product, which measures and regulates its core temperature to vary the accumulated amount of heat;\n(12)‘manual heat charge control with room and/or outdoor temperature feedback’ means a manually operated sensing device integrated into the product which measures its core temperature and varies the accumulated amount of heat in relation with the room temperature and/or outdoor temperature;\n(13)‘electronic heat charge control with room and/or external temperature feedback or regulated by energy supplier’ means an automatically operated sensing device integrated into the product which measures its core temperature and varies the accumulated amount of heat in relation with the room temperature and/or outdoor temperature or a device whose charging regime can be regulated by the energy supplier;\n(14)‘fan assisted heat output’ means the product is equipped with an integrated and controllable fan (or fans) to vary the heat output to adjust to the heat demand;\n(15)‘single stage heat output, no room temperature control’ means the product is not capable of varying its heat output automatically and that no feedback of room temperature is present to adapt the heat output automatically;\n(16)‘two or more manual stages, no room temperature control’ means the product is capable of varying its heat output manually by two or more levels of heat output and is not equipped with a device that automatically regulates the heat output in relation to a desired indoor temperature;\n(17)‘with mechanic thermostat room temperature control’ means the product is equipped with a non-electronic device that allows the product to automatically vary its heat output over a certain time period, in relation to a certain required level of indoor heating comfort;\n(18)‘with electronic room temperature control’ means the product is equipped with an electronic device, either integrated or external, that allows the product to automatically vary its heat output over a certain time period, in relation to a certain required level of indoor heating comfort;\n(19)‘with electronic room temperature control plus day timer’ means the product is equipped with an electronic device, either integrated or external, that allows the product to automatically vary its heat output over a certain time period, in relation to a certain required level of indoor heating comfort, and allows the setting of timing and temperature level for a 24-hours timer interval;\n(20)‘with electronic room temperature control plus week timer’ means the product is equipped with an electronic device, either integrated or external, that allows the product to automatically vary its heat output over a certain time period, in relation to a certain required level of indoor heating comfort, and allows the setting of timing and temperature levels for a full week. During the 7-day period the settings must allow a variation on a day-to-day basis;\n(21)‘room temperature control, with presence detection’ means the product is equipped with an electronic device, either integrated or external, that automatically reduces the set-point for the room temperature when no person is detected in the room;\n(22)‘room temperature control, with open window detection’ means the product is equipped with an electronic device, either integrated or external, that reduces the heat output when a window or door has been opened. Whenever a sensor is used to detect the opening of a window or door, it can be installed with the product, externally to the product, built into the building structure or as a combination of those options;\n(23)‘with distance control option’ means the function that allows remote interaction from outside the building in which the product is installed with the control of the product;\n(24)‘with adaptive start control’ means the function which predicts and initiates the optimal start of heating up in order to reach the set-point temperature at the desired time;\n(25)‘with working time limitation’ means the product has a function that automatically deactivates the product after a pre-set period of time;\n(26)‘with black bulb sensor’ means the product is equipped with an electronic device, either integrated or external, that measures air and radiant temperature;\n(27)‘single stage’ means that the product is not capable of automatically varying its heat output;\n(28)‘two stage’ means the product is capable of automatically regulating its heat output in two distinct levels, in relation to the actual indoor air temperature and a desired indoor air temperature, controlled through temperature sensing devices and an interface which is not necessarily integral to the product itself;\n(29)‘modulating’ means the product is capable of automatically regulating its heat output in three or more distinct levels, in relation to the actual indoor air temperature and a desired indoor air temperature, controlled through temperature sensing devices and an interface which is not necessarily integral to the product itself;\n(30)‘standby mode’ means a condition where the product is connected to the mains power source, depends on energy input from the mains power source to work as intended and provides only the following functions, which may persist for an indefinite time: reactivation function, or reactivation function and only an indication of enabled reactivation function, and/or information or status display;\n(31)‘tube system heat output’ means the combined tube segment heat output of the configuration as it is placed on the market, expressed in kW;\n(32)‘tube segment heat output’ means the heat output of a tube segment which together with other tube segments forms part of a configuration of a tube system, expressed in kW;\n(33)‘radiant factor, at either nominal or minimum heat output’ (RFnom or RFmin respectively) means the ratio of the infrared heat output of the product compared to the total energy input when providing the nominal or minimum heat output, calculated as infrared energy output divided by total energy input on the basis of the net calorific value (NCV) of the fuel when providing the nominal or minimum heat output, expressed in %;\n(34)‘envelope insulation’ means the level of thermal insulation of the product envelope or jacket as applied to minimise heat losses if the product is allowed to be placed outdoors;\n(35)‘envelope loss factor’ means the thermal losses by that part of the product that is installed outside the enclosed space to be heated and which is determined by the transmittance of the relevant envelope of that part, expressed in %;\n(36)‘model identifier’ means the code, usually alphanumeric, which distinguishes a specific local space heater model from other models with the same trade mark or manufacturer's name;\n(37)‘moisture content’ means the mass of water in the fuel in relation to the total mass of the fuel as used in the local space heater.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Annex 1 para. (2) substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 26(7); 2020 c. 1, Sch. 5 para. 1(1)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2015/1188/annex/I",
    "retrieved_at": "2026-11-01T14:46:34.619602+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}