  "legislation_title": "Commission Regulation (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local space heaters (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2015-1188",
  "path": "annex/II/division/1",
  "kind": "division",
  "number": "1",
  "heading": "Specific ecodesign requirements for seasonal space heating energy efficiency",
  "text": "(a) Local space heaters shall comply with the following requirements from 1 January 2018:\n(i) seasonal space heating energy efficiency of open fronted local space heaters using gaseous or liquid fuel shall not be less than 42 %;\n(ii) seasonal space heating energy efficiency of closed fronted local space heaters using gaseous or liquid fuel shall not be less than 72 %;\n(iii) seasonal space heating energy efficiency of electric portable local space heaters shall not be less than 36 %;\n(iv) seasonal space heating energy efficiency of electric fixed local space heaters with a nominal heat output above 250 W shall not be less than 38 %;\n(v) seasonal space heating energy efficiency of electric fixed local space heaters with a nominal heat output equal or below 250 W shall not be less than 34 %;\n(vi) seasonal space heating energy efficiency of electric storage local space heaters shall not be less than 38,5 %;\n(vii) seasonal space heating energy efficiency of electric underfloor local space heaters shall not be less than 38 %;\n(viii) seasonal space heating energy efficiency of electric radiant local space heaters shall not be less than 35 %;\n(ix) seasonal space heating energy efficiency of electric visibly glowing radiant local space heaters with a nominal heat output above 1,2 kW shall not be less than 35 %;\n(x) seasonal space heating energy efficiency of electric visibly glowing radiant local space heaters with a nominal heat output equal or below 1,2 kW shall not be less than 31 %;\n(xi) seasonal space heating energy efficiency of luminous local space heaters shall not be less than 85 %;\n(xii) seasonal space heating energy efficiency of tube local space heaters shall not be less than 74 %.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2015/1188/annex/II/division/1",
    "retrieved_at": "2026-11-01T14:46:34.619602+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}