  "legislation_title": "Commission Regulation (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local space heaters (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2015-1188",
  "path": "annex/II/division/3",
  "kind": "division",
  "number": "3",
  "heading": "Requirements for product information",
  "text": "(a) From 1 January 2018 the following product information on local space heaters shall be provided:\n(i) the instruction manuals for installers and end-users, and free access websites of manufacturers, their authorised representatives and importers shall contain the following elements:\n(1) for gaseous or liquid fuel local space heaters, the information set out in Table 1, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;\n(2) for electric local space heaters, the information set out in Table 2, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;\n(3) for commercial local space heaters, the information set out in Table 3, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;\n(4) any specific precautions that must be taken when the local space heater is assembled, installed or maintained;\n(5) information relevant to disassembly, recycling and/or disposal at end-of-life;\n(ii) the technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:\n(1) the elements specified in point (a);\n(2) a list of all equivalent models, if applicable.\n(b) From 1 January 2018 the following product information on local space heaters shall be provided:\n(i) for flueless local space heaters and open to chimney local space heaters only: the instruction manual for end-users, free access websites of manufacturers and the product packaging shall incorporate the following sentence in such a way to ensure clear visibility and legibility and in a language easily understood by the end-users of the Member State where the product is marketed: ‘This product is not suitable for primary heating purposes’;\n(1) for the instruction manual for end-users this sentence shall be on the cover page of the manual;\n(2) for free-access websites of manufacturers this sentence shall be displayed together with the other characteristics of the product;\n(3) for the product packaging the sentence shall be placed in a prominent position in the packaging when displayed to the end-user prior to purchase;\n(ii) for electric portable local space heaters only: the instruction manual for end-users, free access websites of manufacturers and the product packaging shall incorporate the following sentence in such a way to ensure clear visibility and legibility and in a language easily understood by the end-users of the Member State where the product is marketed: ‘This product is only suitable for well insulated spaces or occasional use.’:\n(1) for the instruction manual for end-users this sentence shall be on the cover page of the manual;\n(2) for free-access websites of manufacturers this sentence shall be displayed together with the other characteristics of the product;\n(3) for the product packaging the sentence shall be placed in a prominent position in the packaging when displayed to the end-user prior to purchase.\nTable 1\nInformation requirements for gaseous/liquid fuel local space heaters\nNOx nitrogen oxides\nModel identifier(s):\nIndirect heating functionality: [yes/no]\nDirect heat output: …(kW)\nIndirect heat output: …(kW)\nFuel\nSpace heating emissions\nNOx\nSelect fuel type\n[gaseous/liquid]\n[specify]\n[mg/kWhinput] (GCV)\nItem\nSymbol\nValue\nUnit\nItem\nSymbol\nValue\nUnit\nHeat output\nUseful efficiency (NCV)\nNominal heat output\nPnom\nx,x\nkW\nUseful efficiency at nominal heat output\nηth,nom\nx,x\n%\nMinimum heat output (indicative)\nPmin\n[x,x/N.A.]\nkW\nUseful efficiency at minimum heat output (indicative)\nηth,min\n[x,x/N.A.]\n%\nAuxiliary electricity consumption\nType of heat output/room temperature control (select one)\nAt nominal heat output\nelmax\nx,xxx\nkW\nsingle stage heat output, no room temperature control\n[yes/no]\nAt minimum heat output\nelmin\nx,xxx\nkW\ntwo or more manual stages, no room temperature control\n[yes/no]\nIn standby mode\nelSB\nx,xxx\nkW\nwith mechanic thermostat room temperature control\n[yes/no]\nwith electronic room temperature control\n[yes/no]\nwith electronic room temperature control plus day timer\n[yes/no]\nwith electronic room temperature control plus week timer\n[yes/no]\nOther control options (multiple selections possible)\nroom temperature control, with presence detection\n[yes/no]\nroom temperature control, with open window detection\n[yes/no]\nwith distance control option\n[yes/no]\nwith adaptive start control\n[yes/no]\nwith working time limitation\n[yes/no]\nwith black bulb sensor\n[yes/no]\nPermanent pilot flame power requirement\nPilot flame power requirement (if applicable)\nPpilot\n[x,xxx/N.A.]\nkW\nContact details\nName and address of the manufacturer or its authorised representative.\nTable 2\nInformation requirements for electric local space heaters\nModel identifier(s):\nItem\nSymbol\nValue\nUnit\nItem\nUnit\nHeat output\nType of heat input, for electric storage local space heaters only (select one)\nNominal heat output\nPnom\nx,x\nkW\nmanual heat charge control, with integrated thermostat\n[yes/no]\nMinimum heat output (indicative)\nPmin\n[x,x/N.A.]\nkW\nmanual heat charge control with room and/or outdoor temperature feedback\n[yes/no]\nMaximum continuous heat output\nPmax,c\nx,x\nkW\nelectronic heat charge control with room and/or outdoor temperature feedback\n[yes/no]\nAuxiliary electricity consumption\nfan assisted heat output\n[yes/no]\nAt nominal heat output\nelmax\nx,xxx\nkW\nType of heat output/room temperature control (select one)\nAt minimum heat output\nelmin\nx,xxx\nkW\nsingle stage heat output and no room temperature control\n[yes/no]\nIn standby mode\nelSB\nx,xxx\nkW\nTwo or more manual stages, no room temperature control\n[yes/no]\nwith mechanic thermostat room temperature control\n[yes/no]\nwith electronic room temperature control\n[yes/no]\nelectronic room temperature control plus day timer\n[yes/no]\nelectronic room temperature control plus week timer\n[yes/no]\nOther control options (multiple selections possible)\nroom temperature control, with presence detection\n[yes/no]\nroom temperature control, with open window detection\n[yes/no]\nwith distance control option\n[yes/no]\nwith adaptive start control\n[yes/no]\nwith working time limitation\n[yes/no]\nwith black bulb sensor\n[yes/no]\nContact details\nName and address of the manufacturer or its authorised representative.\nTable 3\nInformation requirements for commercial local space heaters\nNOx nitrogen oxides.\nFor luminous local space heaters the weighted thermal efficiency is by default 85,6 %.\nModel identifier(s):\nType of heating:[luminous/radiant tube]\nFuel\nFuel\nSpace heating emissions\nNOx\nSelect fuel type\n[gaseous/liquid]\n[specify]\nmg/kWhinput (GCV)\nCharacteristics when operating with the preferred fuel only\nItem\nSymbol\nValue\nUnit\nItem\nSymbol\nValue\nUnit\nHeat output\nUseful efficiency (GCV) — tube local space heaters only\nNominal heat output\nPnom\nx,x\nkW\nUseful efficiency at nominal heat output\nηth,nom\nx,x\n%\nMinimum heat output\nPmin\n[x,x/N.A.]\nkW\nUseful efficiency at minimum heat output\nηth,min\n[x,x/N.A.]\n%\nMinimum heat output (as percentage of nominal heat output)\n..\n[x]\n%\nNominal tube system heat output (if applicable)\nPsystem\nx,x\nkW\nNominal tube segment heat output (if applicable)\nPheater,i\n[x,x/N.A.]\nkW\nUseful efficiency of tube segment at minimum heat output (if applicable)\nηi\n[x,x/N.A.]\n%\n(repeat for multiple segments, if applicable)\n..\n[x,x/N.A.]\nkW\n(repeat for multiple segments, if applicable)\n..\n[x,x/N.A.]\n%\nnumber of identical tube segments\nn\n[x]\n[-]\nRadiant factor\nEnvelope losses\nradiant factor at nominal heat output\nRFnom\n[x,x]\n[-]\nEnvelope insulation class\nU\nW/(m2K)\nradiant factor at minimum heat output\nRFmin\n[x,x]\n[-]\nEnvelope loss factor\nFenv\n[x,x]\n%\nradiant factor of tube segment at nominal heat output\nRFi\n[x,x]\n[-]\nHeat generator to be installed outside the heated area\n[yes/no]\n(repeat for multiple segments, if applicable)\n..\nAuxiliary electricity consumption\nHeat output control type (select one)\nAt nominal heat output\nelmax\nx,xxx\nkW\n—\nsingle stage\n[yes/no]\nAt minimum heat output\nelmin\nx,xxx\nkW\n—\ntwo stage\n[yes/no]\nIn standby mode\nelSB\nx,xxx\nkW\n—\nmodulating\n[yes/no]\nPermanent pilot flame power requirement\nPilot flame power requirement (if applicable)\nPpilot\n[x,xxx/N.A.]\nkW\nContact details\nName and address of the manufacturer or its authorised representative.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "NOx nitrogen oxides"
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "NOx nitrogen oxides."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "For luminous local space heaters the weighted thermal efficiency is by default 85,6 %."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2015/1188/annex/II/division/3",
    "retrieved_at": "2026-11-01T14:46:34.619602+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}