# Commission Regulation (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local space heaters (Text with EEA relevance), Division 3: Requirements for product information

Extent: E+W+S+N.I.

(a) From 1 January 2018 the following product information on local space heaters shall be provided:
(i) the instruction manuals for installers and end-users, and free access websites of manufacturers, their authorised representatives and importers shall contain the following elements:
(1) for gaseous or liquid fuel local space heaters, the information set out in Table 1, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;
(2) for electric local space heaters, the information set out in Table 2, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;
(3) for commercial local space heaters, the information set out in Table 3, with its technical parameters measured and calculated in accordance with Annex III and showing the significant figures indicated in the table;
(4) any specific precautions that must be taken when the local space heater is assembled, installed or maintained;
(5) information relevant to disassembly, recycling and/or disposal at end-of-life;
(ii) the technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:
(1) the elements specified in point (a);
(2) a list of all equivalent models, if applicable.
(b) From 1 January 2018 the following product information on local space heaters shall be provided:
(i) for flueless local space heaters and open to chimney local space heaters only: the instruction manual for end-users, free access websites of manufacturers and the product packaging shall incorporate the following sentence in such a way to ensure clear visibility and legibility and in a language easily understood by the end-users of the Member State where the product is marketed: ‘This product is not suitable for primary heating purposes’;
(1) for the instruction manual for end-users this sentence shall be on the cover page of the manual;
(2) for free-access websites of manufacturers this sentence shall be displayed together with the other characteristics of the product;
(3) for the product packaging the sentence shall be placed in a prominent position in the packaging when displayed to the end-user prior to purchase;
(ii) for electric portable local space heaters only: the instruction manual for end-users, free access websites of manufacturers and the product packaging shall incorporate the following sentence in such a way to ensure clear visibility and legibility and in a language easily understood by the end-users of the Member State where the product is marketed: ‘This product is only suitable for well insulated spaces or occasional use.’:
(1) for the instruction manual for end-users this sentence shall be on the cover page of the manual;
(2) for free-access websites of manufacturers this sentence shall be displayed together with the other characteristics of the product;
(3) for the product packaging the sentence shall be placed in a prominent position in the packaging when displayed to the end-user prior to purchase.
Table 1
Information requirements for gaseous/liquid fuel local space heaters
NOx nitrogen oxides
Model identifier(s):
Indirect heating functionality: [yes/no]
Direct heat output: …(kW)
Indirect heat output: …(kW)
Fuel
Space heating emissions
NOx
Select fuel type
[gaseous/liquid]
[specify]
[mg/kWhinput] (GCV)
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Heat output
Useful efficiency (NCV)
Nominal heat output
Pnom
x,x
kW
Useful efficiency at nominal heat output
ηth,nom
x,x
%
Minimum heat output (indicative)
Pmin
[x,x/N.A.]
kW
Useful efficiency at minimum heat output (indicative)
ηth,min
[x,x/N.A.]
%
Auxiliary electricity consumption
Type of heat output/room temperature control (select one)
At nominal heat output
elmax
x,xxx
kW
single stage heat output, no room temperature control
[yes/no]
At minimum heat output
elmin
x,xxx
kW
two or more manual stages, no room temperature control
[yes/no]
In standby mode
elSB
x,xxx
kW
with mechanic thermostat room temperature control
[yes/no]
with electronic room temperature control
[yes/no]
with electronic room temperature control plus day timer
[yes/no]
with electronic room temperature control plus week timer
[yes/no]
Other control options (multiple selections possible)
room temperature control, with presence detection
[yes/no]
room temperature control, with open window detection
[yes/no]
with distance control option
[yes/no]
with adaptive start control
[yes/no]
with working time limitation
[yes/no]
with black bulb sensor
[yes/no]
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable)
Ppilot
[x,xxx/N.A.]
kW
Contact details
Name and address of the manufacturer or its authorised representative.
Table 2
Information requirements for electric local space heaters
Model identifier(s):
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output
Pnom
x,x
kW
manual heat charge control, with integrated thermostat
[yes/no]
Minimum heat output (indicative)
Pmin
[x,x/N.A.]
kW
manual heat charge control with room and/or outdoor temperature feedback
[yes/no]
Maximum continuous heat output
Pmax,c
x,x
kW
electronic heat charge control with room and/or outdoor temperature feedback
[yes/no]
Auxiliary electricity consumption
fan assisted heat output
[yes/no]
At nominal heat output
elmax
x,xxx
kW
Type of heat output/room temperature control (select one)
At minimum heat output
elmin
x,xxx
kW
single stage heat output and no room temperature control
[yes/no]
In standby mode
elSB
x,xxx
kW
Two or more manual stages, no room temperature control
[yes/no]
with mechanic thermostat room temperature control
[yes/no]
with electronic room temperature control
[yes/no]
electronic room temperature control plus day timer
[yes/no]
electronic room temperature control plus week timer
[yes/no]
Other control options (multiple selections possible)
room temperature control, with presence detection
[yes/no]
room temperature control, with open window detection
[yes/no]
with distance control option
[yes/no]
with adaptive start control
[yes/no]
with working time limitation
[yes/no]
with black bulb sensor
[yes/no]
Contact details
Name and address of the manufacturer or its authorised representative.
Table 3
Information requirements for commercial local space heaters
NOx nitrogen oxides.
For luminous local space heaters the weighted thermal efficiency is by default 85,6 %.
Model identifier(s):
Type of heating:[luminous/radiant tube]
Fuel
Fuel
Space heating emissions
NOx
Select fuel type
[gaseous/liquid]
[specify]
mg/kWhinput (GCV)
Characteristics when operating with the preferred fuel only
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Heat output
Useful efficiency (GCV) — tube local space heaters only
Nominal heat output
Pnom
x,x
kW
Useful efficiency at nominal heat output
ηth,nom
x,x
%
Minimum heat output
Pmin
[x,x/N.A.]
kW
Useful efficiency at minimum heat output
ηth,min
[x,x/N.A.]
%
Minimum heat output (as percentage of nominal heat output)
..
[x]
%
Nominal tube system heat output (if applicable)
Psystem
x,x
kW
Nominal tube segment heat output (if applicable)
Pheater,i
[x,x/N.A.]
kW
Useful efficiency of tube segment at minimum heat output (if applicable)
ηi
[x,x/N.A.]
%
(repeat for multiple segments, if applicable)
..
[x,x/N.A.]
kW
(repeat for multiple segments, if applicable)
..
[x,x/N.A.]
%
number of identical tube segments
n
[x]
[-]
Radiant factor
Envelope losses
radiant factor at nominal heat output
RFnom
[x,x]
[-]
Envelope insulation class
U
W/(m2K)
radiant factor at minimum heat output
RFmin
[x,x]
[-]
Envelope loss factor
Fenv
[x,x]
%
radiant factor of tube segment at nominal heat output
RFi
[x,x]
[-]
Heat generator to be installed outside the heated area
[yes/no]
(repeat for multiple segments, if applicable)
..
Auxiliary electricity consumption
Heat output control type (select one)
At nominal heat output
elmax
x,xxx
kW
—
single stage
[yes/no]
At minimum heat output
elmin
x,xxx
kW
—
two stage
[yes/no]
In standby mode
elSB
x,xxx
kW
—
modulating
[yes/no]
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable)
Ppilot
[x,xxx/N.A.]
kW
Contact details
Name and address of the manufacturer or its authorised representative.

---