Division 6 Seasonal space heating emissions
United Kingdom
- (a)
Emissions of particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides shall be expressed standardised to a dry flue gas basis at 10 % oxygen and standard conditions at 0 °C and 1 013 millibar.
- (b)
The seasonal space heating emissions Es of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides are calculated as follows:
- (1)
for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and for automatically stoked solid fuel boilers:
Es = 0,85 × Es,p + 0,15 × Es,n
- (2)
for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and for solid fuel cogeneration boilers:
Es = Es,n
where:
- (a)
Es,p are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at 30 % or 50 % of rated heat output, as applicable;
- (b)
Es,n are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at rated heat output.
- (1)
- (c)
Emissions of particulate matter shall be measured by a gravimetric method excluding any particulate matter formed by organic gaseous compounds when flue gas is mixed with ambient air.
- (d)
Emissions of nitrogen oxides shall be calculated as the sum of nitrogen monoxide and nitrogen dioxide, and expressed in nitrogen dioxide.