# Commission Regulation (EU) 2017/1151 of 1 June 2017 supplementing Regulation (EC) No 715/2007 of the European Parliament and of the Council on type-approval of motor vehicles with respect to emissions from light passenger and commercial vehicles (Euro 5 and Euro 6) and on access to vehicle repair and maintenance information, amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) No 1230/2012 and repealing Commission Regulation (EC) No 692/2008 (Text with EEA relevance), Division 3.4.3.3.3.1: The air flow rate, Qs at each test point shall be calculated from the flow meter data using the manufacturer's prescribed method.


Values of the calibration coefficient shall be calculated for each test point:
Kv=QsTvPv
where:
Qsis the flow rate, m3/min at 273,15 K (0 °C) and 101,325, kPa;
Tvis the temperature at the venturi inlet, Kelvin (K);
Pvis the absolute pressure at the venturi inlet, kPa.

---
Source: https://www.legislation.gov.uk/eur/2017/1151/annex/Sub/5/division/division/3./division/3.4./division/3.4.3./division/3.4.3.3.3.1. (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-1151/annex-Sub/5/division/division-3./division-3.4./division-3.4.3./division-3.4.3.3.3.1.