# Commission Regulation (EU) 2017/1151 of 1 June 2017 supplementing Regulation (EC) No 715/2007 of the European Parliament and of the Council on type-approval of motor vehicles with respect to emissions from light passenger and commercial vehicles (Euro 5 and Euro 6) and on access to vehicle repair and maintenance information, amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) No 1230/2012 and repealing Commission Regulation (EC) No 692/2008 (Text with EEA relevance), Division 3.5.1.1.1: Critical flow orifice (CFO) method


The CFO method meters a constant flow of pure gas (CO, CO2, or C3H8) using a critical flow orifice device.
A known mass of pure carbon monoxide, carbon dioxide or propane gas shall be introduced into the CVS system through the calibrated critical orifice. If the inlet pressure is high enough, the flow rate q which is restricted by means of the critical flow orifice, is independent of orifice outlet pressure (critical flow). The CVS system shall be operated as in a normal exhaust emissions test and enough time shall be allowed for subsequent analysis. The gas collected in the sample bag shall be analysed by the usual equipment (paragraph 4.1. of this Sub-Annex) and the results compared to the concentration of the known gas samples If deviations exceed 2 per cent, the cause of the malfunction shall be determined and corrected.

---
Source: https://www.legislation.gov.uk/eur/2017/1151/annex/Sub/5/division/division/3./division/3.5./division/3.5.1./division/3.5.1.1.1. (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-1151/annex-Sub/5/division/division-3./division-3.5./division-3.5.1./division-3.5.1.1.1.
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.