# Commission Regulation (EU) 2017/1151 of 1 June 2017 supplementing Regulation (EC) No 715/2007 of the European Parliament and of the Council on type-approval of motor vehicles with respect to emissions from light passenger and commercial vehicles (Euro 5 and Euro 6) and on access to vehicle repair and maintenance information, amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) No 1230/2012 and repealing Commission Regulation (EC) No 692/2008 (Text with EEA relevance), Division 4.2.1.2.3: The sampled dilute exhaust gas shall be maintained at a temperature above 20 °C and below 52 °C within 20 cm upstream or downstream of the particulate sampling filter face. Heating or insulation of components of the particulate sampling system to achieve this is permitted.


In the event that the 52 °C limit is exceeded during a test where periodic regeneration event does not occur, the CVS flow rate shall be increased or double dilution shall be applied (assuming that the CVS flow rate is already sufficient so as not to cause condensation within the CVS, sample bags or analytical system).

---
Source: https://www.legislation.gov.uk/eur/2017/1151/annex/Sub/5/division/division/4./division/4.2./division/4.2.1./division/4.2.1.2./division/4.2.1.2.3. (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-1151/annex-Sub/5/division/division-4./division-4.2./division-4.2.1./division-4.2.1.2./division-4.2.1.2.3.
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.