# Commission Regulation (EU) 2017/1151 of 1 June 2017 supplementing Regulation (EC) No 715/2007 of the European Parliament and of the Council on type-approval of motor vehicles with respect to emissions from light passenger and commercial vehicles (Euro 5 and Euro 6) and on access to vehicle repair and maintenance information, amending Directive 2007/46/EC of the European Parliament and of the Council, Commission Regulation (EC) No 692/2008 and Commission Regulation (EU) No 1230/2012 and repealing Commission Regulation (EC) No 692/2008 (Text with EEA relevance), Division 4.4.2.1.3: The phase-specific pure electric-range PERp for PEVs shall be calculated from the Type 1 test as described in paragraph 3.4.4.2. of this Sub-Annex by using the following equations:


PERp=UBESTPECDC,p
where:
UBESTPis the usable REESS energy in accordance with paragraph 4.4.2.1.1. of this Sub-Annex, Wh;
ECDC,pis the weighted electric energy consumption for each individual phase of DS1 and DS2 of the shortened Type 1 test procedure, Wh/km;
In the case that phase p = low and phase p = medium, the following equations shall be used:
ECDC,p=∑j= 14 ECDC,p,j× Kp,j
where:
ECDC,p,jis the electric energy consumption for phase p where the first phase p of DS1 is indicated as j = 1, the second phase p of DS1 is indicated as j = 2, the first phase p of DS2 is indicated as j = 3 and the second phase p of DS2 is indicated as j = 4 of the shortened Type 1 test procedure according to paragraph 4.3. of this Sub-Annex, Wh/km;
Kp,jis the weighting factor for phase p where the first phase p of DS1 is indicated as j = 1, the second phase p of DS1 is indicated as j = 2, the first phase p of DS2 is indicated as j = 3, and the second phase p of DS2 is indicated as j = 4 of the shortened Type 1 test procedure;
and
Kp,1=ΔEREESS,p,1UBESTPand Kp,j=1− Kp,13 for j= 2 ... 4
where:
ΔEREESS,p,1is the energy change of all REESSs during the first phase p of DS1 of the shortened Type 1 test procedure, Wh.
In the case that phase p = high and phase p = extraHigh, the following equations shall be used:
ECDC,p=∑j= 12 ECDC,p,j× Kp,j
where:
ECDC,p,jis the electric energy consumption for phase p of DSj of the shortened Type 1 test procedure according to paragraph 4.3. of this Sub-Annex, Wh/km;
kp,jis the weighting factor for phase p of DSj of the shortened Type 1 test procedure
and
Kp,1=ΔEREESS,p,1UBESTP and Kp,2= 1− Kp,1
where:
ΔEREESS,p,1is the electric energy change of all REESSs during the first phase p of DS1 of the shortened Type 1 test procedure, Wh.

---
Source: https://www.legislation.gov.uk/eur/2017/1151/annex/Sub/8n1/division/division/4./division/4.4./division/4.4.2./division/4.4.2.1./division/4.4.2.1.3. (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-1151/annex-Sub/8n1/division/division-4./division-4.4./division-4.4.2./division-4.4.2.1./division-4.4.2.1.3.
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.