OpenLegislation

Annex

United Kingdom

Original text. Later amendments are not shown.

Table 1

Classes of reaction to fire performance for cross laminated timber products and laminated veneer lumber products for walls and ceilings

Applies to all species and glues covered by the product standards.

Conditioned in accordance with standard EN 13238.

Class as set out in Table 1 of the Annex to Delegated Regulation (EU) 2016/364.

Class valid for any substrate or air gap behind.

Productf1 Product detailMinimum mean densityf2 (kg/m3)Minimum overall thickness (mm)Classf3
Cross laminated timber products covered by the harmonised standard EN 16351Minimum layer thickness of 18 mm35054D-s2, d0f4
Laminated veneer lumber products covered by the harmonised standard EN 14374Minimum veneer thickness of 3 mm40018D-s2, d0

Table 2

Classes of reaction to fire performance for cross laminated timber products and laminated veneer lumber products for floorings

Applies also to steps of stairs.

Conditioned in accordance with standard EN 13238.

Class as set out in Table 2 of the Annex to Delegated Regulation (EU) 2016/364.

Class valid for any substrate or air gap behind.

Productf5 Product detailMinimum mean densityf6 (kg/m3)Minimum overall thickness (mm)Class for flooringsf7
Cross laminated timber products covered by the harmonised standard EN 16351minimum layer thickness of 18 mm and with the surface layer made of pine43054DFL-s1f8
Cross laminated timber products covered by the harmonised standard EN 16351minimum layer thickness of 18 mm and with the surface layer made of spruce40054DFL-s1
Laminated veneer lumber products covered by the harmonised standard EN 14374with a minimum veneer thickness of 3 mm and with the surface layer made of pine48015DFL-s1
Laminated veneer lumber products covered by the harmonised standard EN 14374with a minimum veneer thickness of 3 mm and with the surface layer made of pine43020DFL-s1
Laminated veneer lumber products covered by the harmonised standard EN 14374with a minimum veneer thickness of 3 mm and with the surface layer made of spruce40015DFL-s1

Annotations

Footnotes

f1

Applies to all species and glues covered by the product standards.

f2

Conditioned in accordance with standard EN 13238.

f3

Class as set out in Table 1 of the Annex to Delegated Regulation (EU) 2016/364.

f4

Class valid for any substrate or air gap behind.

f5

Applies also to steps of stairs.

f6

Conditioned in accordance with standard EN 13238.

f7

Class as set out in Table 2 of the Annex to Delegated Regulation (EU) 2016/364.

f8

Class valid for any substrate or air gap behind.