# Commission Regulation (EU) 2017/2400 of 12 December 2017 implementing Regulation (EC) No 595/2009 of the European Parliament and of the Council as regards the determination of the CO2 emissions and fuel consumption of heavy-duty vehicles and amending Directive 2007/46/EC of the European Parliament and of the Council and Commission Regulation (EU) No 582/2011 (Text with EEA relevance), Division 3.1: Fan

Extent: E+W+S+N.I.

For the fan power the standard values shown in Table 1 shall be used depending on mission profile and technology:
Table 1
Mechanical power demand of the fan
Fan drive cluster
Fan control
Fan power consumption [W]
Long haul
Regional delivery
Urban delivery
Municipal utility
Construction
Crankshaft mounted
Electronically controlled visco clutch
618
671
516
566
1 037
Bimetallic controlled visco clutch
818
871
676
766
1 277
Discrete step clutch
668
721
616
616
1 157
On/off cluch
718
771
666
666
1 237
Belt driven or driven via transmission
Electronic controlled visco clutch
989
1 044
833
933
1 478
Bimetallic controlled visco clutch
1 189
1 244
993
1 133
1 718
Discrete step clutch
1 039
1 094
983
983
1 598
On/off cluch
1 089
1 144
1 033
1 033
1 678
Hydraulically driven
Variable displacement pump
938
1 155
832
917
1 872
Constant displacement pump
1 200
1 400
1 000
1 100
2 300
Electrically driven
Electronically
700
800
600
600
1 400
If a new technology within a fan drive cluster (e.g. crankshaft mounted) cannot be found in the list the highest power values within that cluster shall be taken. If a new technology cannot be found in any cluster the values of the worst technology at all shall be taken (hydraulic driven constant displacement pump)

---