Appendix 2
United Kingdom
Additional technical requirements on NOx control measures for engines of categories IWP, IWA and RLR, including the method to demonstrate these strategies
1.
Introduction
This Appendix sets out the additional requirements to ensure the correct operation of NOx control measures for engines of categories IWP, IWA and RLR.
F12.
General requirements
The requirements of Appendix 1 apply to engines in scope of this Appendix, except as set out in points 3 and 4 of this Appendix.
3.
Exceptions to the requirements of Appendix 1
In order to account for safety concerns the operator inducement system set out in points 5 and 11.3 of Appendix 1 shall not apply to engines under the scope of this Appendix. The requirement to store data in an on-board computer log set out in point 4 of this Appendix shall apply wherever the inducement would have been activated in accordance with points 2.3.2.3.2, 6.3, 7.3, 8.4 and 9.4 of Appendix 1.
4.
Requirement for storing incidents of engine operation with inadequate reagent injection or reagent quality
4.1.
The on-board computer log must record in non-volatile computer memory or counters the total number and duration of all incidents of engine operation with inadequate reagent injection or reagent quality in a manner to ensure that the information cannot be intentionally deleted.
4.1.1.
It shall be possible for national inspection authorities to read these records with a scan tool.
4.1.2.
A description of the connection for, and method to read, these records shall be included in the information folder as set out in Part A of Annex I of Implementing Regulation (EU) 2017/656.
4.2.
The duration of an incident of inadequate reagent level recorded in the on-board computer log as specified in point 4.1, in place of an inducement in accordance with point 6.3 of Appendix 1, shall commence when the reagent tank becomes empty, that is, when the dosing system is unable to draw further reagent from the tank, or at any level below 2,5 % of its nominally full capacity at the discretion of the manufacturer.
4.3.
The duration of an incident recorded in the on-board computer log as specified in point 4.1, in place of the inducement specified in points 6.3, 7.3, 8.4 and 9.4 of Appendix 1, shall commence when the respective counter reaches the value for severe inducement in Table 4.4 of Appendix 1.
4.4.
The duration of an incident recorded in the on-board computer log as specified in point 4.1, in place of the inducement specified in point 2.3.2.3.2 of Appendix 1, shall commence when inducement would have commenced.
4.5.
The duration of an incident recorded in the on-board computer log as specified in point 4.1 shall end when the incident has been remedied.
F24.6.
When conducting a demonstration pursuant to section 10.4 of Appendix 1, the demonstration shall be conducted in accordance with the requirements applicable to demonstration of the severe inducement system, but the demonstration of severe inducement system shall be replaced by a demonstration of the storage of an incident of engine operation with inadequate reagent injection or reagent quality.