# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.10.1.1: Scope and frequency

Extent: E+W+S+N.I.

For all FID analyzers, the FID shall be calibrated upon initial installation. The calibration shall be repeated as needed using good engineering judgment. The following steps shall be performed for a FID that measures HC:
(a) A FID's response to various hydrocarbons shall be optimized after initial analyzer installation and after major maintenance. FID response to propylene and toluene shall be between 0,9 and 1,1 relative to propane;
(b) A FID's methane (CH4) response factor shall be determined after initial analyzer installation and after major maintenance as described in point 8.1.10.1.4;
(c) Methane (CH4) response shall be verified within 185 days before testing.

---