# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.11.1.3: System requirements

Extent: E+W+S+N.I.

For dilute measurement a CLD analyzer shall not exceed a combined H2O and CO2 quench of ± 2 %. For raw measurement a CLD analyzer shall not exceed a combined H2O and CO2 quench of ± 2,5 %. Combined quench is the sum of the CO2 quench determined as described in point 8.1.11.1.4 and the H2O quench as determined in point 8.1.11.1.5. If these requirements are not met, corrective action shall be taken by repairing or replacing the analyzer. Before running emission tests, it shall be verified that the corrective action have successfully restored the analyzer to proper functioning.

---
Source: https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.11/division/8.1.11.1/division/8.1.11.1.3 (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.1/division-8.1.11/division-8.1.11.1/division-8.1.11.1.3
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.