  "url": "https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.1/division-8.1.11/division-8.1.11.2/division-8.1.11.2.3",
  "json_url": "https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.1/division-8.1.11/division-8.1.11.2/division-8.1.11.2.3.json",
  "legislation": "eur/2017/654",
  "legislation_title": "Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2017-654",
  "path": "annex/VI/division/8/division/8.1/division/8.1.11/division/8.1.11.2/division/8.1.11.2.3",
  "kind": "division",
  "number": "8.1.11.2.3",
  "heading": "Combined H2O and CO2 quench calculations",
  "text": "Combined H2O and CO2 quench shall be calculated by means of equation (6-23):\nquench = x NOwet 1 − x H2Omeas x NOdry × x H2Oexp x H2Omeas + x NOmeas x NOact − 1 × x CO2exp x CO2act × 100 %\n(6-23)\nWhere:\nquench = amount of CLD quench\nx NOdry is the measured concentration of NO upstream of a bubbler, in accordance with point 8.1.11.1.5(d)\nx NOwet is the measured concentration of NO downstream of a bubbler, in accordance with point 8.1.11.1.5(i)\nx H2Oexp is the maximum expected mole fraction of water during emission testing in accordance with point 8.1.11.2.1.\nx H2Omeas is the measured mole fraction of water during the quench verification in accordance with point 8.1.11.1.5(g)\nx NOmeas is the measured concentration of NO when NO span gas is blended with CO2 span gas, in accordance with point 8.1.11.1.4(j)\nx NOact is the actual concentration of NO when NO span gas is blended with CO2 span gas, in accordance with point 8.1.11.1.4(k) and calculated by means of equation (6-24)\nx CO2exp is the maximum expected concentration of CO2 during emission testing, in accordance with point 8.1.11.2.2.\nx CO2act is the actual concentration of CO2 when NO span gas is blended with CO2 span gas, in accordance with point 8.1.11.1.4(i)\nx NOact = 1 − x CO2act x CO2span × x NOspan\n(6-24)\nWhere:\nx NOspan is the NO span gas concentration input to the gas divider, in accordance with point 8.1.11.1.4(e)\nx CO2span is the CO2 span gas concentration input to the gas divider, in accordance with point 8.1.11.1.4(d)",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.11/division/8.1.11.2/division/8.1.11.2.3",
    "retrieved_at": "2026-11-01T14:45:01.864924+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}