OpenLegislation

Division 8.1.11.4.2 Measurement principles

United Kingdom

Original text. Later amendments are not shown.

A sample dryer removes water, which can otherwise interfere with a NOx measurement. However, liquid water remaining in an improperly designed F1sample dryer can remove NO2 from the sample. If a sample dryer is used without an NO2-to-NO converter upstream, it could therefore remove NO2 from the sample prior NOx measurement.

Annotations

Textual amendments

F1

Substituted by Commission Delegated Regulation (EU) 2018/989 of 18 May 2018 amending and correcting Delegated Regulation (EU) 2017/654 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery (Text with EEA relevance).