# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.11.5.4: Procedure

Extent: E+W+S+N.I.

The following procedure shall be used to verify the performance of a NO2-to-NO converter:
(a) For the instrument setup the analyzer and NO2-to-NO converter manufacturers' start-up and operating instructions shall be followed. The analyzer and converter shall be adjusted as needed to optimize performance;
(b) An ozonator's inlet shall be connected to a zero-air or oxygen source and its outlet shall be connected to one port of a 3-way tee fitting. An NO span gas shall be connected to another port and the NO2-to-NO converter inlet shall be connected to the last port;
(c) The following steps shall be taken when performing this check:
(i) The ozonator air shall be set off and the ozonator power shall be turned off and the NO2-to-NO converter shall be set to the bypass mode (i.e., NO mode). Stabilization shall be allowed for, accounting only for transport delays and instrument response;
(ii) The NO and zero-gas flows shall be adjusted so the NO concentration at the analyzer is near the peak total NOx concentration expected during testing. The NO2 content of the gas mixture shall be less than 5 % of the NO concentration. The concentration of NO shall be recorded by calculating the mean of 30 s of sampled data from the analyzer and this value shall be recorded as x NOref. Higher concentration may be used according to the instrument manufacturer's recommendation and good engineering judgement in order to obtain accurate verification, if the expected NO concentration is lower than the minimum range for the verification specified by the instrument manufacturer;
(iii) The ozonator O2 supply shall be turned on and the O2 flow rate adjusted so that the NO indicated by the analyzer is about 10 percent less than x NOref. The concentration of NO shall be recorded by calculating the mean of 30 s of sampled data from the analyzer and this value recorded as x NO+O2mix;
(iv) The ozonator shall be switched on and the ozone generation rate adjusted so that the NO measured by the analyzer is approximately 20 percent of x NOref, while maintaining at least 10 % unreacted NO. The concentration of NO shall be recorded by calculating the mean of 30 s of sampled data from the analyzer and this value shall be recorded as x NOmeas;
(v) The NOx analyzer shall be switched to NOx mode and total NOx measured. The concentration of NOx shall be recorded by calculating the mean of 30 s of sampled data from the analyzer and this value shall be recorded as x NOxmeas;
(vi) The ozonator shall be switched off but gas flow through the system shall be maintained. The NOx analyzer will indicate the NOx in the NO + O2 mixture. The concentration of NOx shall be recorded by calculating the mean of 30 s of sampled data from the analyzer and this value shall be recorded as x NOx+O2mix;
(vii) O2 supply shall be turned off. The NOx analyzer will indicate the NOx in the original NO-in-N2 mixture. The concentration of NOx shall be recorded by calculating the mean of 30 s of sampled data from the analyzer and this value shall be recorded as x NOxref. This value shall be no more than 5 % above the x NOref value;
(d) Performance evaluation. The efficiency of the NOx converter shall be calculated by substituting the concentrations obtained into equation (6-26):
Efficiency % = 1 + x NOxmeas − x NOx + O2mix x NO + O2mix − x NOmeas × 100
(6-26)
(e) If the result is less than 95 %, the NO2-to-NO converter shall be repaired or replaced.

---