OpenLegislation

Division 8.1.13.2.5 Correction calculationF1

United Kingdom

Original text. Later amendments are not shown.

The PM sample filter shall be corrected for buoyancy by means of equation (6-27):

m cor = m uncor × 1 − ρ air ρ weight 1 − ρ air ρ media (6-27)

Where:

m cor
  • is the PM sample filter mass corrected for buoyancy

  • m uncor
  • is the PM sample filter mass uncorrected for buoyancy

  • ρ air
  • is the density of air in balance environment

  • ρ weight
  • is the density of calibration weight used to span balance

  • ρ media
  • is the density of PM sample filter

  • with

    ρ air = p abs × M mix R × T amb (6-28)

    Where:

    p abs
  • is the absolute pressure in balance environment

  • M mix
  • is the molar mass of air in balance environment

  • R
  • is the molar gas constant.

  • T amb
  • is the absolute ambient temperature of balance environment

  • Annotations

    Textual amendments

    F1

    Inserted by Commission Delegated Regulation (EU) 2018/989 of 18 May 2018 amending and correcting Delegated Regulation (EU) 2017/654 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery (Text with EEA relevance).