  "legislation_title": "Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2017-654",
  "path": "annex/VI/division/8/division/8.1/division/8.1.4/division/8.1.4.5",
  "kind": "division",
  "number": "8.1.4.5",
  "heading": "Measurement systems that require linearity verification",
  "text": "Table 6.5 indicates measurement systems that require linearity verifications. For this Table the following provisions shall apply:\n(a) a linearity verification shall be performed more frequently if the instrument manufacturer recommends it or based on good engineering judgment;\n(b) ‘min’ refers to the minimum reference value used during the linearity verification;\nNote that this value may be zero or a negative value depending on the signal;\n(c) ‘max’ generally refers to the maximum reference value used during the linearity verification. For example for gas dividers, x max is the undivided, undiluted, span gas concentration. The following are special cases where ‘max’ refers to a different value:\n(i) For PM balance linearity verification, m max refers to the typical mass of a PM filter;\n(ii) For torque linearity verification, T max refers to the manufacturer's specified engine torque peak value of the highest torque engine to be tested;\n(d) the specified ranges are inclusive. For example, a specified range of 0,98-1,02 for the slope a 1 means 0,98 ≤ a 1 ≤ 1,02;\n(e) these linearity verifications are not required for systems that pass the flow-rate verification for diluted exhaust gas as described in point 8.1.8.5 for the propane check or for systems that agree within ± 2 % based on a chemical balance of carbon or oxygen of the intake air, fuel, and exhaust gas;\n(f) a 1 criteria for these quantities shall be met only if the absolute value of the quantity is required, as opposed to a signal that is only linearly proportional to the actual value;\n(g) stand-alone temperatures include engine temperatures and ambient conditions used to set or verify engine conditions; temperatures used to set or verify critical conditions in the test system; and temperatures used in emissions calculations:\n(i) these temperature linearity checks are required. Air intake; after-treatment bed(s) (for engines tested with exhaust after-treatment systems on cycles with cold start criteria); dilution air for PM sampling (CVS, double dilution, and partial flow systems); PM sample; and chiller sample (for gaseous sampling systems that use chillers to dry samples);\n(ii) these temperature linearity checks are only required if specified by the engine manufacturer. Fuel inlet; test cell charge air cooler air outlet (for engines tested with a test cell heat exchanger simulating a non-road mobile machinery charge air cooler); test cell charge air cooler coolant inlet (for engines tested with a test cell heat exchanger simulating a non-road mobile machinery charge air cooler); and oil in the sump/pan; coolant before the thermostat (for liquid cooled engines);\n(h) stand-alone pressures include engine pressures and ambient conditions used to set or verify engine conditions; pressures used to set or verify critical conditions in the test system; and pressures used in emissions calculations:\n(i) required pressure linearity checks are: intake air pressure restriction; exhaust gas back-pressure; barometer; CVS inlet gage pressure (if measurement using CVS); chiller sample (for gaseous sampling systems that use chillers to dry samples);\n(ii) pressure linearity checks that are required only if specified by the engine manufacturer: test cell charge air cooler and interconnecting pipe pressure drop (for turbo-charged engines tested with a test cell heat exchanger simulating a non-road mobile machinery charge air cooler) fuel inlet; and fuel outlet.\nTable 6.5\nMeasurement systems that require linearity verifications\nMolar flow rate may be used instead of standard volumetric flow rate as the term representing ‘quantity’. In this case maximum molar flow rate may be used instead of the maximum standard volumetric flow rate in the corresponding linearity criteria.\nMeasurement System\nQuantity\nMinimum verification frequency\nLinearity Criteria\nx min × a 1 − 1 + a 0\nα\nSEE\nr 2\nEngine speed\nn\nWithin 370 days before testing\n≤ 0,05 % n max\n0,98-1,02\n≤ 2 % n max\n≥ 0,990\nEngine torque\nT\nWithin 370 days before testing\n≤ 1 % T max\n0,98-1,02\n≤ 2 % T max\n≥ 0,990\nFuel flow rate\nqm\nWithin 370 days before testing\n≤ 1 % qm , max\n0,98-1,02\n≤ 2 % qm , max\n≥ 0,990\nIntake-air flow rate\nqV\nWithin 370 days before testing\n≤ 1 % qV , max\n0,98-1,02\n≤ 2 % qV , max\n≥ 0,990\nDilution air flow rate\nqV\nWithin 370 days before testing\n≤ 1 % qV , max\n0,98-1,02\n≤ 2 % qV , max\n≥ 0,990\nDiluted exhaust gas flow rate\nqV\nWithin 370 days before testing\n≤ 1 % qV , max\n0,98-1,02\n≤ 2 % qV , max\n≥ 0,990\nRaw exhaust gas flow rate\nqV\nWithin 185 days before testing\n≤ 1 % qV , max\n0,98-1,02\n≤ 2 % qV , max\n≥ 0,990\nBatch sampler flow rates\nqV\nWithin 370 days before testing\n≤ 1 % qV , max\n0,98-1,02\n≤ 2 % qV , max\n≥ 0,990\nGas dividers\nx/x span\nWithin 370 days before testing\n≤ 0,5 % x max\n0,98-1,02\n≤ 2 % x max\n≥ 0,990\nGas analyzers\nx\nWithin 35 days before testing\n≤ 0,5 % x max\n0,99-1,01\n≤ 1 % x max\n≥ 0,998\nPM balance\nm\nWithin 370 days before testing\n≤ 1 % m max\n0,99-1,01\n≤ 1 % m max\n≥ 0,998\nStand-alone pressures\np\nWithin 370 days before testing\n≤ 1 % p max\n0,99-1,01\n≤ 1 % p max\n≥ 0,998\nAnalog-to-digital conversion of stand-alone temperature signals\nT\nWithin 370 days before testing\n≤ 1 % T max\n0,99-1,01\n≤ 1 % T max\n≥ 0,998",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "Molar flow rate may be used instead of standard volumetric flow rate as the term representing ‘quantity’. In this case maximum molar flow rate may be used instead of the maximum standard volumetric flow rate in the corresponding linearity criteria."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.4/division/8.1.4.5",
    "retrieved_at": "2026-11-01T14:45:01.864924+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}