  "legislation_title": "Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2017-654",
  "path": "annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.4/division/8.1.8.4.2",
  "kind": "division",
  "number": "8.1.8.4.2",
  "heading": "PDP calibration",
  "text": "A positive-displacement pump (PDP) shall be calibrated to determine a flow-versus-PDP speed equation that accounts for flow leakage across sealing surfaces in the PDP as a function of PDP inlet pressure. Unique equation coefficients shall be determined for each speed at which the PDP is operated. A PDP flow meter shall be calibrated as follows:\n(a) The system shall be connected as shown in Figure 6.5;\n(b) Leaks between the calibration flow meter and the PDP shall be less than 0,3 % of the total flow at the lowest calibrated flow point; for example, at the highest pressure restriction and lowest PDP-speed point;\n(c) While the PDP operates, a constant temperature at the PDP inlet shall be maintained within ± 2 % of the mean absolute inlet temperature, T in;\n(d) The PDP speed is set to the first speed point at which it is intended to calibrate;\n(e) The variable restrictor is set to its wide-open position;\n(f) The PDP is operated for at least 3 minutes to stabilize the system. Then by continuously operating the PDP, the mean values of at least 30 s of sampled data of each of the following quantities are recorded:\n(i) The mean flow rate of the reference flow meter, q – V ref ;\n(ii) The mean temperature at the PDP inlet, T in;\n(iii) The mean static absolute pressure at the PDP inlet, p in;\n(iv) The mean static absolute pressure at the PDP outlet, p out;\n(v) The mean PDP speed, n PDP;\n(g) The restrictor valve shall be incrementally closed to decrease the absolute pressure at the inlet to the PDP, p in;\n(h) The steps in paragraphs 8.1.8.4.2(f) and (g) shall be repeated to record data at a minimum of six restrictor positions reflecting the full range of possible in-use pressures at the PDP inlet;\n(i) The PDP shall be calibrated by using the collected data and the equations set out in Annex VII;\n(j) The steps in paragraphs (f) to (i) of this point shall be repeated for each speed at which the PDP is operated;\n(k) The equations in section 3 of Annex VII (molar based approach) or section 2 of Annex VII (mass based approach) shall be used to determine the PDP flow equation for emission testing;\n(l) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in point 8.1.8.5;\n(m) The PDP may not be used below the lowest inlet pressure tested during calibration.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.4/division/8.1.8.4.2",
    "retrieved_at": "2026-11-01T14:45:01.864924+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}