# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.8.4.2: PDP calibration

Extent: E+W+S+N.I.

A positive-displacement pump (PDP) shall be calibrated to determine a flow-versus-PDP speed equation that accounts for flow leakage across sealing surfaces in the PDP as a function of PDP inlet pressure. Unique equation coefficients shall be determined for each speed at which the PDP is operated. A PDP flow meter shall be calibrated as follows:
(a) The system shall be connected as shown in Figure 6.5;
(b) Leaks between the calibration flow meter and the PDP shall be less than 0,3 % of the total flow at the lowest calibrated flow point; for example, at the highest pressure restriction and lowest PDP-speed point;
(c) While the PDP operates, a constant temperature at the PDP inlet shall be maintained within ± 2 % of the mean absolute inlet temperature, T in;
(d) The PDP speed is set to the first speed point at which it is intended to calibrate;
(e) The variable restrictor is set to its wide-open position;
(f) The PDP is operated for at least 3 minutes to stabilize the system. Then by continuously operating the PDP, the mean values of at least 30 s of sampled data of each of the following quantities are recorded:
(i) The mean flow rate of the reference flow meter, q – V ref ;
(ii) The mean temperature at the PDP inlet, T in;
(iii) The mean static absolute pressure at the PDP inlet, p in;
(iv) The mean static absolute pressure at the PDP outlet, p out;
(v) The mean PDP speed, n PDP;
(g) The restrictor valve shall be incrementally closed to decrease the absolute pressure at the inlet to the PDP, p in;
(h) The steps in paragraphs 8.1.8.4.2(f) and (g) shall be repeated to record data at a minimum of six restrictor positions reflecting the full range of possible in-use pressures at the PDP inlet;
(i) The PDP shall be calibrated by using the collected data and the equations set out in Annex VII;
(j) The steps in paragraphs (f) to (i) of this point shall be repeated for each speed at which the PDP is operated;
(k) The equations in section 3 of Annex VII (molar based approach) or section 2 of Annex VII (mass based approach) shall be used to determine the PDP flow equation for emission testing;
(l) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in point 8.1.8.5;
(m) The PDP may not be used below the lowest inlet pressure tested during calibration.

---
Source: https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.4/division/8.1.8.4.2 (the official version)
Page: https://openlegislation.uk/eu-regulation-2017-654/annex-VI/division-8/division-8.1/division-8.1.8/division-8.1.8.4/division-8.1.8.4.2