# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.8.4.3: CFV calibration

Extent: E+W+S+N.I.

A critical-flow venturi (CFV) shall be calibrated to verify its discharge coefficient, C d, at the lowest expected static differential pressure between the CFV inlet and outlet. A CFV flow meter shall be calibrated as follows:
(a) The system shall be connected as shown in Figure 6.5;
(b) The blower shall be started downstream of the CFV;
(c) While the CFV operates, a constant temperature at the CFV inlet shall be maintained within ± 2 % of the mean absolute inlet temperature, T in;
(d) Leaks between the calibration flow meter and the CFV shall be less than 0,3 % of the total flow at the highest pressure restriction;
(e) The variable restrictor shall be set to its wide-open position. In lieu of a variable restrictor the pressure downstream of the CFV may be varied by varying blower speed or by introducing a controlled leak. Note that some blowers have limitations on non-loaded conditions;
(f) The CFV shall be operated for at least 3 minutes to stabilize the system. The CFV shall continue operating and the mean values of at least 30 s of sampled data of each of the following quantities shall be recorded:
(i) The mean flow rate of the reference flow meter, q – V ref ;
(ii) Optionally, the mean dew point of the calibration air, T dew. See Annex VII for permissible assumptions during emission measurements;
(iii) The mean temperature at the venturi inlet, T in;
(iv) The mean static absolute pressure at the venturi inlet, p in;
(v) The mean static differential pressure between the CFV inlet and the CFV outlet, Δp CFV;
(g) The restrictor valve shall be incrementally closed to decrease the absolute pressure at the inlet to the CFV, p in;
(h) The steps in paragraphs (f) and (g) of this point shall be repeated to record mean data at a minimum of ten restrictor positions, such that the fullest practical range of Δp CFV expected during testing is tested. It is not required to remove calibration components or CVS components to calibrate at the lowest possible pressure restrictions;
(i) Cd and the highest allowable pressure ratio r shall be determined as described in Annex VII;
(j) Cd shall be used to determine CFV flow during an emission test. The CFV shall not be used above the highest allowed r, as determined in Annex VII;
(k) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in point 8.1.z8.5;
(l) If the CVS is configured to operate more than one CFV at a time in parallel, the CVS shall be calibrated by one of the following:
(i) Every combination of CFVs shall be calibrated according to this section and with Annex VII. See Annex VII for instructions on calculating flow rates for this option;
(ii) Each CFV shall be calibrated according to this point and Annex VII. See Annex VII for instructions on calculating flow rates for this option.

---