  "legislation_title": "Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2017-654",
  "path": "annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.4/division/8.1.8.4.4",
  "kind": "division",
  "number": "8.1.8.4.4",
  "heading": "SSV calibration",
  "text": "A subsonic venturi (SSV) shall be calibrated to determine its calibration coefficient, C d, for the expected range of inlet pressures. An SSV flow meter shall be calibrated as follows:\n(a) The system shall be connected as shown in Figure 6.5;\n(b) The blower shall be started downstream of the SSV;\n(c) Leaks between the calibration flow meter and the SSV shall be less than 0,3 % of the total flow at the highest pressure restriction;\n(d) While the SSV operates, a constant temperature at the SSV inlet shall be maintained within ± 2 % of the mean absolute inlet temperature, T in;\n(e) The variable restrictor or variable-speed blower shall be set to a flow rate greater than the greatest flow rate expected during testing. Flow rates may not be extrapolated beyond calibrated values, so it is recommended that it is made certain that a Reynolds number, Re, at the SSV throat at the greatest calibrated flow rate is greater than the maximum Re expected during testing;\n(f) The SSV shall be operated for at least 3 min to stabilize the system. The SSV shall continue operating and the mean of at least 30 s of sampled data of each of the following quantities shall be recorded:\n(i) The mean flow rate of the reference flow meter, q – V ref ;\n(ii) Optionally, the mean dew point of the calibration air, T dew. See Annex VII for permissible assumptions;\n(iii) The mean temperature at the venturi inlet, T in;\n(iv) The mean static absolute pressure at the venturi inlet, p in;\n(v) Static differential pressure between the static pressure at the venturi inlet and the static pressure at the venturi throat, Δp SSV;\n(g) The restrictor valve shall be incrementally closed or the blower speed decreased to decrease the flow rate;\n(h) The steps in paragraphs (f) and (g) of this point shall be repeated to record data at a minimum of ten flow rates;\n(i) A functional form of C d versus Re shall be determined by using the collected data and the equations in Annex VII;\n(j) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in point 8.1.8.5 using the new C d versus Re equation;\n(k) The SSV shall be used only between the minimum and maximum calibrated flow rates;\n(l) The equations in section 3 of Annex VII (molar based approach) or section 2 of Annex VII (mass based approach) shall be used to determine SSV flow during a test.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2017/654/annex/VI/division/8/division/8.1/division/8.1.8/division/8.1.8.4/division/8.1.8.4.4",
    "retrieved_at": "2026-11-01T14:45:01.864924+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}