# Commission Delegated Regulation (EU) 2017/654 of 19 December 2016 supplementing Regulation (EU) 2016/1628 of the European Parliament and of the Council with regard to technical and general requirements relating to emission limits and type-approval for internal combustion engines for non-road mobile machinery, Division 8.1.8.4.4: SSV calibration

Extent: E+W+S+N.I.

A subsonic venturi (SSV) shall be calibrated to determine its calibration coefficient, C d, for the expected range of inlet pressures. An SSV flow meter shall be calibrated as follows:
(a) The system shall be connected as shown in Figure 6.5;
(b) The blower shall be started downstream of the SSV;
(c) Leaks between the calibration flow meter and the SSV shall be less than 0,3 % of the total flow at the highest pressure restriction;
(d) While the SSV operates, a constant temperature at the SSV inlet shall be maintained within ± 2 % of the mean absolute inlet temperature, T in;
(e) The variable restrictor or variable-speed blower shall be set to a flow rate greater than the greatest flow rate expected during testing. Flow rates may not be extrapolated beyond calibrated values, so it is recommended that it is made certain that a Reynolds number, Re, at the SSV throat at the greatest calibrated flow rate is greater than the maximum Re expected during testing;
(f) The SSV shall be operated for at least 3 min to stabilize the system. The SSV shall continue operating and the mean of at least 30 s of sampled data of each of the following quantities shall be recorded:
(i) The mean flow rate of the reference flow meter, q – V ref ;
(ii) Optionally, the mean dew point of the calibration air, T dew. See Annex VII for permissible assumptions;
(iii) The mean temperature at the venturi inlet, T in;
(iv) The mean static absolute pressure at the venturi inlet, p in;
(v) Static differential pressure between the static pressure at the venturi inlet and the static pressure at the venturi throat, Δp SSV;
(g) The restrictor valve shall be incrementally closed or the blower speed decreased to decrease the flow rate;
(h) The steps in paragraphs (f) and (g) of this point shall be repeated to record data at a minimum of ten flow rates;
(i) A functional form of C d versus Re shall be determined by using the collected data and the equations in Annex VII;
(j) The calibration shall be verified by performing a CVS verification (i.e., propane check) as described in point 8.1.8.5 using the new C d versus Re equation;
(k) The SSV shall be used only between the minimum and maximum calibrated flow rates;
(l) The equations in section 3 of Annex VII (molar based approach) or section 2 of Annex VII (mass based approach) shall be used to determine SSV flow during a test.

---